Monitoring of a biogas process using electronic gas sensors and near-infrared spectroscopy (NIR).

A Nordberg1, M Hansson, I Sundh, E Nordkvist, H Carisson, B Mathisen.   

Abstract

The use of electronic gas sensors and near-infrared spectroscopy (NIR) to monitor the dynamics in a biogas process was evaluated using multivariate data analysis. The digester, a completely stirred 8 l tank reactor fed with a mixture of cellulose, albumin and minerals, was exposed to an overload of glucose after which monitoring of electronic gas sensor responses, NIR spectra as well as traditional chemical variables and analysis of microbial community structure were done. The responses from an array of electronic gas sensors consisting of MOS and MOSFET-sensors were correlated against volatile compounds in the headspace using partial least square (PLS) regressions. The root mean square error of prediction (RMSEP) was 0.15 g/l for acetate in the range of 0.14-1.72 g/l and the RMSEP for methane was 2.3% in the range of 27-73%. Selected wavelengths from the second derivative of the original NIR spectra (400-2500 nm) resulted in a PLS-model for predicting microbial biomass, measured as total phospholipid fatty acids, with a RMSEP of 9 nmol/ml in the range of 163-293 nmol/ml. The NIR model developed for acetate had a RMSEP of 0.20 g/l within the range of 0.14-1.72 g/l. The results clearly show that both NIR and an array of electronic gas sensors can provide simultaneous non-invasive in situ monitoring of important process variables in anaerobic digesters.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11381979

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  3 in total

Review 1.  Sensor systems, electronic tongues and electronic noses, for the monitoring of biotechnological processes.

Authors:  Alisa Rudnitskaya; Andrey Legin
Journal:  J Ind Microbiol Biotechnol       Date:  2008-01-09       Impact factor: 3.346

2.  Gas sensing of SnO2 nanocrystals revisited: developing ultra-sensitive sensors for detecting the H2S leakage of biogas.

Authors:  Lin Mei; Yuejiao Chen; Jianmin Ma
Journal:  Sci Rep       Date:  2014-08-12       Impact factor: 4.379

3.  Automatic carbon dioxide-methane gas sensor based on the solubility of gases in water.

Authors:  Raúl O Cadena-Pereda; Eric M Rivera-Muñoz; Gilberto Herrera-Ruiz; Domingo J Gomez-Melendez; Ely K Anaya-Rivera
Journal:  Sensors (Basel)       Date:  2012-08-06       Impact factor: 3.576

  3 in total