Literature DB >> 11381388

The use of computed tomography to define zygomatic complex position.

I M Furst1, P Austin, M Pharoah, J Mahoney.   

Abstract

PURPOSE: The purpose of this study was to analyze the use of midline references and landmarks to assess the position of the zygomatic complex relative to the cranial base, and to test the reliability of these measurements in assessing facial symmetry.
METHODS: Direct skull measurements were compared with measurements made on computed tomography (CT) images. The effect of CT scanner error, technologist error, gantry angle error, error of skull inclination, and error due to the presence of titanium rigid fixation hardware were assessed. To test observer variation and the effect of each level of error, 4 blinded bilateral measurements were repeated 3 times by 5 observers on both dry skull and CT scans. A mixed effect analysis of variance model then assessed for effect of method of measurement (dry skull vs CT), observer, CT scanner, technologist, gantry angle, skull inclination, and rigid fixation.
RESULTS: A total of 2,040 measurements were made. Measurements for zygomatic complex posterior and anterior width and height were reliable and had an interobserver variations of 0.02 +/- 0.03 mm, 0.5 +/- 0.4 mm, and 0.37 +/- 0.3 mm, respectively. The difference between dry skull and CT assessment for the 3 reliable measurements was 1.2 +/- 0.3 mm, 0.44 +/- 0.4 mm, and 1.1 +/- 0.5 mm, respectively. The errors produced by the CT scanner, technologist, and rigid internal fixation hardware were not clinically significant. The measurements were not sensitive to gantry angle and skull inclination changes of 10 degrees or less. A fourth measurement assessing zygomatic complex projection was found not to be accurate or reliable.
CONCLUSIONS: These findings suggest that the 3 CT scan measurements describing the position of the zygomatic complex relative to the cranial base are clinically useful. Copyright 2001 American Association of Oral and Maxillofacial Surgeons.

Mesh:

Substances:

Year:  2001        PMID: 11381388     DOI: 10.1053/joms.2001.23394

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  4 in total

1.  Evaluation of soft tissue asymmetry using cone-beam computed tomography after open reduction and internal fixation of zygomaticomaxillary complex fracture.

Authors:  Dong Hyuck Kim; Rae Hyong Kim; Jun Lee; Young Deok Chee; Kyung Hwan Kwon; Kyoung-Hwan Kwon
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-06-27

2.  A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry.

Authors:  W W B de Kort; W M M T van Hout; T C Ten Harkel; E M van Cann; A J W P Rosenberg
Journal:  J Craniofac Surg       Date:  2021-12-03       Impact factor: 1.172

3.  Are temporary anchorage devices truly effective in the treatment of skeletal open bites?

Authors:  Hakan Turkkahraman; Mehmet Sarioglu
Journal:  Eur J Dent       Date:  2016 Oct-Dec

4.  Radiographic evaluation of percutaneous transfacial wiring versus open internal fixation for surgical treatment of unstable zygomatic bone fractures.

Authors:  Guillaume Giran; Arnaud Paré; Benjamin Croisé; Carine Koudougou; Jacques Marie Mercier; Boris Laure; Pierre Corre; Hélios Bertin
Journal:  PLoS One       Date:  2019-08-15       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.