Literature DB >> 11380135

Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw.

O Olsson1, L Ceder, A Hauggaard.   

Abstract

We compared 54 patients treated by a Medoff sliding plate (MSP) with 60 stabilised by a compression hip screw (CHS) in a prospective, randomised study of the management of intertrochanteric femoral fractures. Four months after the operation femoral shortening was determined from radiographs of both femora. In unstable fractures the mean femoral shortening was 15 mm with the MSP and 11 mm with the CHS (p = 0.03). A subgroup in which shortening was classified as large, comprising one-third of the patients in each group, had a similar extent of shortening, but more medialisation of the femoral shaft occurred in the CHS (26%) than in the MSP (12%) group (p = 0.03). Five postoperative failures of fixation occurred with the CHS and none with the MSP (p = 0.03). The marginally greater femoral shortening seen with the MSP compared with the CHS appeared to be justified by the improved control of impaction of the fracture. Biaxial dynamisation in unstable intertrochanteric fractures is a safe principle of treatment, which minimises the rate of postoperative failure of fixation.

Entities:  

Mesh:

Year:  2001        PMID: 11380135     DOI: 10.1302/0301-620x.83b4.11302

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  10 in total

1.  Is helical blade nailing superior to locked minimally invasive plating in unstable pertrochanteric fractures?

Authors:  Matthias Knobe; Wolf Drescher; Nicole Heussen; Richard Martin Sellei; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2012-02-07       Impact factor: 4.176

2.  Femoral shaft medialisation and neck-shaft angle in unstable pertrochanteric femoral fractures.

Authors:  J Pajarinen; J Lindahl; V Savolainen; O Michelsson; E Hirvensalo
Journal:  Int Orthop       Date:  2004-09-10       Impact factor: 3.075

Review 3.  Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis.

Authors:  Sharon R Lewis; Richard Macey; Joseph Lewis; Jamie Stokes; James R Gill; Jonathan A Cook; William Gp Eardley; Martyn J Parker; Xavier L Griffin
Journal:  Cochrane Database Syst Rev       Date:  2022-02-10

Review 4.  Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.

Authors:  Martyn J Parker; Avishek Das
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28

Review 5.  Influence of osteoporosis on fracture fixation--a systematic literature review.

Authors:  J Goldhahn; N Suhm; S Goldhahn; M Blauth; B Hanson
Journal:  Osteoporos Int       Date:  2008-06       Impact factor: 4.507

6.  Locked plating versus cephalomedullary nailing of unstable intertrochanteric femur fractures.

Authors:  Philipp N Streubel; Michael Moustoukas; William T Obremskey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-02-26

7.  Femoral morphology is associated with development of knee pain after hip fracture injury among older adults: A nine-year retrospective study.

Authors:  Yoichi Kaizu; Kazuhiro Miyata; Hironori Arii; Masayuki Tazawa; Takehiko Yamaji
Journal:  J Orthop       Date:  2021-02-22

8.  Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail.

Authors:  Yi Zhu; Severin Meili; Changqing Zhang; Congfeng Luo; Bing-fang Zeng
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-09-01       Impact factor: 2.953

9.  Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

Authors:  Johnny Paulsson; Josefine Corin Stig; Ola Olsson
Journal:  BMC Musculoskelet Disord       Date:  2017-08-24       Impact factor: 2.362

10.  Increased Fracture Collapse after Intertrochanteric Fractures Treated by the Dynamic Hip Screw Adversely Affects Walking Ability but Not Survival.

Authors:  Christian Fang; Paata Gudushauri; Tak-Man Wong; Tak-Wing Lau; Terence Pun; Frankie Leung
Journal:  Biomed Res Int       Date:  2016-02-03       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.