Literature DB >> 11380031

Transvenous embolization of small patent ductus arteriosus with single detachable coils in dogs.

M Schneider1, N Hildebrandt, T Schweigl, I Schneider, K H Hagel, H Neu.   

Abstract

Transvenous embolization of small patent ductus arteriosus (PDA; < or = 4 mm) with a single detachable coil was attempted in 24 dogs (median age 5.7 months, range, 2.6-65.5 months; median body weight 5.5 kg, range, 1.5-30.0 kg). Angiographic imaging of the duct and pressure measurements were made before and after embolization. The minimal ductal diameter was 2.7 +/- 0.7 mm. In all dogs, a single coil was employed regardless of residual shunting. Ten dogs (PDA minimal diameter range, 1.5-2.2 mm) received a 5-mm coil, and 14 dogs (PDA minimal diameter range, 2.9-3.6 mm) received a 8-mm coil. After coil embolization the angiographic shunt grade decreased significantly (n = 20, P < .001). Residual shunts were assessed by angiography 15 minutes after and by Doppler echocardiography 1-3 days and 3 months after the intervention. In the dogs treated with the 5-mm coils the residual shunt rate was low (0%, 10%, and 0% for angiography and Doppler echocardiography at 1-3 days and 3 months, respectively), in contrast to the dogs treated with the 8-mm coils (91%, 79%, and 67% for angiography and Doppler echocardiography at 1-3 days and 3 months, respectively). After 3 months, no residual murmur was found in dogs treated with the 5-mm coils (0/7), in contrast to murmurs in 5 of 12 (42%) dogs treated with the 8-mm coils. Despite incomplete closure in these dogs, volume loading of the left heart decreased in all dogs. Pulmonic or aortic coil embolism did not occur. Analysis of initial results shows that single detachable coil embolization is possible in all dogs with a small PDA (< or = 4 mm), but only very small PDA (< or = 2.5) could be treated effectively, and for the moderate PDA (2.6-4.0 mm) longer coils or multiple coils may be necessary to achieve complete occlusion.

Entities:  

Mesh:

Year:  2001        PMID: 11380031     DOI: 10.1892/0891-6640(2001)015<0222:teospd>2.3.co;2

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  5 in total

1.  Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: patent ductus arteriosus and vascular rings.

Authors:  Christiane R Henjes; Ingo Nolte; Patrick Wefstaedt
Journal:  BMC Vet Res       Date:  2011-09-23       Impact factor: 2.741

2.  Retrieval of an embolization coil accidentally dislodged in the descending aorta of a dog with a patent ductus arteriosus.

Authors:  Seung Gon Lee; Changbaig Hyun
Journal:  J Vet Sci       Date:  2007-06       Impact factor: 1.672

3.  Transvenous embolization of moderate to large patent ductus arteriosus in dogs using the Amplatzer vascular plug II.

Authors:  Nicolai Hildebrandt; Andreas Stosic; Estelle Henrich; Nicola Wiedemann; Gabriel Wurtinger; Matthias Schneider
Journal:  J Vet Intern Med       Date:  2021-12-16       Impact factor: 3.333

4.  Transjugular Patent Ductus Arteriosus Occlusion in Seven Dogs Using the Amplatzer Vascular Plug II.

Authors:  Mara Bagardi; Oriol Domenech; Tommaso Vezzosi; Federica Marchesotti; Martina Bini; Valentina Patata; Marta Croce; Valentina Valenti; Luigi Venco
Journal:  Vet Sci       Date:  2022-08-14

5.  Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs.

Authors:  Alma H Hulsman; Johannes M P J Breur; Viktor Szatmári
Journal:  J Vet Intern Med       Date:  2020-11-26       Impact factor: 3.175

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.