Literature DB >> 11379993

Effect of insertion torque on bone screw pullout strength.

K J Lawson1, J Brems.   

Abstract

The effect of insertion torque on the holding strength of 4.5-mm ASIF/AO cortical bone screws was studied in vitro. Screw holding strength was determined using an Instron materials testing machine (Bristol, United Kingdom) on 55 lamb femora and 30 human tibiocortical bone sections. Holding strength was defined as tensile stress at pullout with rapid loading to construct failure. Different insertion torques were tested, normalizing to the thickness of cortical bone specimen engaged. These represented low, intermediate, high, and thread-damaging insertion torque. All screws inserted with thread-damaging torque and single cortex engaging screws inserted to high torque tightening moments showed diminished holding strength. This loss of strength amounted to 40%-50% less than screws inserted with less torque.

Entities:  

Mesh:

Year:  2001        PMID: 11379993     DOI: 10.3928/0147-7447-20010501-12

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Can high-friction intraannular material increase screw pullout strength in osteoporotic bone?

Authors:  Daniel Bronsnick; Ryan E Harold; Ari Youderian; Giovanni Solitro; Farid Amirouche; Benjamin Goldberg
Journal:  Clin Orthop Relat Res       Date:  2014-10-02       Impact factor: 4.176

2.  Stripping torques in human bone can be reliably predicted prior to screw insertion with optimum tightness being found between 70% and 80% of the maximum.

Authors:  James W A Fletcher; Ivan Zderic; Boyko Gueorguiev; R Geoff Richards; Harinderjit S Gill; Michael R Whitehouse; Ezio Preatoni
Journal:  Bone Joint Res       Date:  2020-09-03       Impact factor: 5.853

3.  Evaluation of the internal fixation effect of nano-calcium-deficient hydroxyapatite/poly-amino acid composite screws for intraarticular fractures in rabbits.

Authors:  Zhenyu Dai; Yue Li; Yonggang Yan; Ruijie Wan; Qiang Ran; Weizhong Lu; Bo Qiao; Hong Li
Journal:  Int J Nanomedicine       Date:  2018-10-18

4.  Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopaedic surgeons.

Authors:  James W A Fletcher; Verena Neumann; Lisa Wenzel; Boyko Gueorguiev; R Geoff Richards; Harinderjit S Gill; Michael R Whitehouse; Ezio Preatoni
Journal:  J Orthop Surg Res       Date:  2021-10-26       Impact factor: 2.359

  4 in total