Literature DB >> 11379418

Pulse dye densitometry: a novel bedside monitor of circulating blood volume.

R W Goy1, J W Chiu, C C Loo.   

Abstract

INTRODUCTION: Monitoring of circulating blood volume is important in the management of critically ill patients. Current methods of circulating blood volume measurements such as indicator dilution using radioisotopes or Evans blue dye are unsuitable for clinical application as these tests do not allow for frequent repeated measurements to be done. A direct bedside measurement of circulating blood volume using the principle of pulse dye densitometry was recently introduced. This is essentially an indicator dilution technique using indocyanine green combined with the principle of pulse spectrophotometry.
METHODS: This paper aims to review this method of circulating blood volume measurement and provide a summary of the published clinical trials that compared its accuracy with the other conventional methods of circulating blood volume measurement, based on a Medline search, spanning the period 1966 to August 2000.
RESULTS: Published studies show that pulse dye densitometry gives comparable results when compared to other conventional methods of blood volume measurement. Its ability to measure circulating blood volume accurately and repeatedly, as frequently as every 20 min makes it suitable for clinical application.
CONCLUSION: Pulse dye densitometry provides for a rapid, semi-noninvasive and convenient bedside assessment of circulating blood volume that is applicable clinically. Further studies are needed to ascertain the impact of the use of pulse dye densitometry on the mortality and morbidity of the critically ill.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11379418

Source DB:  PubMed          Journal:  Ann Acad Med Singapore        ISSN: 0304-4602            Impact factor:   2.473


  4 in total

Review 1.  [Determinants of insensible fluid loss. Perspiration, protein shift and endothelial glycocalyx].

Authors:  M Jacob; D Chappell; K Hofmann-Kiefer; P Conzen; K Peter; M Rehm
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

2.  In vivo multispectral photoacoustic and photothermal flow cytometry with multicolor dyes: a potential for real-time assessment of circulation, dye-cell interaction, and blood volume.

Authors:  Mikhail A Proskurnin; Tatyana V Zhidkova; Dmitry S Volkov; Mustafa Sarimollaoglu; Ekaterina I Galanzha; Donald Mock; Dmitry A Nedosekin; Vladimir P Zharov
Journal:  Cytometry A       Date:  2011-09-08       Impact factor: 4.355

Review 3.  Therapeutic hypertension: principles and methods.

Authors:  David J Powner; Joseph M Darby; John W Crommett; Robert L Levine
Journal:  Neurosurg Rev       Date:  2004-08-14       Impact factor: 3.042

4.  Exploring the Link Between Hepatic Perfusion and Endotoxemia in Hemodialysis.

Authors:  Raanan Marants; Elena Qirjazi; Ka-Bik Lai; Cheuk-Chun Szeto; Philip K T Li; Fiona Li; Ting-Yim Lee; Christopher W McIntyre
Journal:  Kidney Int Rep       Date:  2021-02-09
  4 in total