Three parallel-imaging methods were implemented and compared in terms of artifact and noise content: original SMASH, Cartesian SENSE, and an extremely simple method called here the "scissors method." These methods represent very different approaches to the parallel-imaging problem. The experimental and numerical comparisons presented here aim at shedding light on the whole spectrum of parallel-imaging methods, not just the three methods actually implemented. In our results, SMASH images had an artifact level significantly higher than SENSE images for all acceleration factors. The SNR in SENSE images was nearly optimal at low acceleration factors. As acceleration was increased, the noise content in SENSE images eventually sharply departed from optimal values, while the artifact content remained low. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11378889     DOI: 10.1002/mrm.1145

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Optimization of diffusion-tensor MR imaging data acquisition parameters for brain fiber tracking using parallel imaging at 3 T.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Hisashi Kawai; Hiroshi Fukatsu; Takeo Ishigaki; Katsuya Maruyama; Osamu Takizawa
Journal:  Eur Radiol       Date:  2003-11-19       Impact factor: 5.315

2.  Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences.

Authors:  C Fink; M Puderbach; S Ley; J Zaporozhan; C Plathow; H-U Kauczor
Journal:  Eur Radiol       Date:  2005-06-30       Impact factor: 5.315

3.  MR imaging of the cervical spine: assessment of image quality with parallel imaging compared to non-accelerated MR measurements.

Authors:  Iris-M Noebauer-Huhmann; Christian Glaser; Olaf Dietrich; Claus-Peter Wallner; Wolfgang Klinger; Herwig Imhof; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

4.  Efficacy of double arterial phase dynamic magnetic resonance imaging with the sensitivity encoding technique versus dynamic multidetector-row helical computed tomography for detecting hypervascular hepatocellular carcinoma.

Authors:  Seishi Kumano; Masahiko Uemura; Toyoaki Haraikawa; Masaaki Hirata; Keiichi Kikuchi; Tonsok Kim; Masahiro Okada; Teruhito Mochizuki; Takamichi Murakami
Journal:  Jpn J Radiol       Date:  2009-07-22       Impact factor: 2.374

5.  Time-resolved MR angiography: optimal parallel imaging method.

Authors:  J-Y Gauvrit; M Law; J Xu; R Carson; P Sunenshine; Q Chen
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

6.  High-resolution structural and functional assessments of cerebral microvasculature using 3D Gas ΔR2*-mMRA.

Authors:  Chien-Hsiang Huang; Chiao-Chi V Chen; Tiing-Yee Siow; Sheng-Hsiou S Hsu; Yi-Hua Hsu; Fu-Shan Jaw; Chen Chang
Journal:  PLoS One       Date:  2013-11-04       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.