Literature DB >> 11378882

Two-component diffusion tensor MRI of isolated perfused hearts.

E W Hsu1, D L Buckley, J D Bui, S J Blackband, J R Forder.   

Abstract

Nonmonoexponential MR diffusion decay behavior has been observed at high diffusion-weighting strengths for cell aggregates and tissues, including the myocardium; however, implications for myocardial MR diffusion tensor imaging are largely unknown. In this study, a slow-exchange-limit, two-component diffusion tensor model was fitted to diffusion-weighted images obtained in isolated, perfused rat hearts. Results indicate that there are at least two distinct components of anisotropic diffusion, characterized by a "fast" component whose principal diffusivity is comparable to that of the perfusate, and a highly anisotropic "slow" component. It is speculated that the two components correspond to tissue compartments and have a general agreement with the orientations of anisotropy, or fiber orientations, in the myocardium. Moreover, consideration of previous studies of myocardial diffusion suggests that the presently observed fast component may likely be dominated by diffusion in the vascular space, whereas the slow component may include the intracellular and interstitial compartments. The implications of the results for myocardial fiber orientation mapping and limitations of the current two-component model used are also discussed. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11378882     DOI: 10.1002/mrm.1138

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

Review 1.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

2.  Diffusive sensitivity to muscle architecture: a magnetic resonance diffusion tensor imaging study of the human calf.

Authors:  Craig J Galbán; Stefan Maderwald; Kai Uffmann; Armin de Greiff; Mark E Ladd
Journal:  Eur J Appl Physiol       Date:  2004-12       Impact factor: 3.078

3.  Anisotropic hydraulic permeability under finite deformation.

Authors:  Gerard A Ateshian; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

4.  Orientation dependence of microcirculation-induced diffusion signal in anisotropic tissues.

Authors:  Osama M Abdullah; Arnold David Gomez; Samer Merchant; Michael Heidinger; Steven Poelzing; Edward W Hsu
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

5.  Diffusion tensor imaging and histology of developing hearts.

Authors:  Osama M Abdullah; Thomas Seidel; MarJanna Dahl; Arnold David Gomez; Gavin Yiep; Julia Cortino; Frank B Sachse; Kurt H Albertine; Edward W Hsu
Journal:  NMR Biomed       Date:  2016-08-03       Impact factor: 4.044

6.  Higher-Order Motion-Compensation for In Vivo Cardiac Diffusion Tensor Imaging in Rats.

Authors:  Christopher L Welsh; Edward V R DiBella; Edward W Hsu
Journal:  IEEE Trans Med Imaging       Date:  2015-03-09       Impact factor: 10.048

7.  In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches.

Authors:  Sonia Nielles-Vallespin; Choukri Mekkaoui; Peter Gatehouse; Timothy G Reese; Jennifer Keegan; Pedro F Ferreira; Steve Collins; Peter Speier; Thorsten Feiweier; Ranil de Silva; Marcel P Jackowski; Dudley J Pennell; David E Sosnovik; David Firmin
Journal:  Magn Reson Med       Date:  2012-09-21       Impact factor: 4.668

8.  Ex vivo diffusion tensor MRI reflects microscopic structural remodeling associated with aging and disease progression in normal and cardiomyopathic Syrian hamsters.

Authors:  Wen Li; Ming Lu; Suhanti Banerjee; Jia Zhong; Allen Ye; Joseph Molter; Xin Yu
Journal:  NMR Biomed       Date:  2009-10       Impact factor: 4.044

9.  Characterization of diffuse fibrosis in the failing human heart via diffusion tensor imaging and quantitative histological validation.

Authors:  Osama M Abdullah; Stavros G Drakos; Nikolaos A Diakos; Omar Wever-Pinzon; Abdallah G Kfoury; Josef Stehlik; Craig H Selzman; Bruce B Reid; Kim Brunisholz; Divya Ratan Verma; Craig Myrick; Frank B Sachse; Dean Y Li; Edward W Hsu
Journal:  NMR Biomed       Date:  2014-09-09       Impact factor: 4.044

10.  Comparison of diffusion tensor imaging by cardiovascular magnetic resonance and gadolinium enhanced 3D image intensity approaches to investigation of structural anisotropy in explanted rat hearts.

Authors:  Olivier Bernus; Aleksandra Radjenovic; Mark L Trew; Ian J LeGrice; Gregory B Sands; Derek R Magee; Bruce H Smaill; Stephen H Gilbert
Journal:  J Cardiovasc Magn Reson       Date:  2015-04-29       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.