Different responses of ear and finger pulse oximeter wave form to cold pressor test.

A A Awad1, M A Ghobashy, W Ouda, R G Stout, D G Silverman, K H Shelley.   

Abstract

The cold pressor test is often used to assess vasoconstrictive responses because it simulates the vasoconstrictive challenges commonly encountered in the clinical setting. With IRB approval, 12 healthy volunteers, aged 25--50 yr, underwent baseline plethysmographic monitoring on the finger and ear. The contralateral hand was immersed in ice water for 30 s to elicit a systemic vasoconstrictive response while the recordings were continued. The changes in plethysmographic amplitude for the first 30 s of ice water immersion (period of maximum response) of the finger and ear were compared. The data indicate a significant disparity between the finger and the ear signals in response to the cold stimulus. The average finger plethysmographic amplitude measurement decreased by 48% +/- 19%. In contrast, no significant change was seen in the ear plethysmographic amplitude measurement, which decreased by 2% +/- 10%. We conclude that the ear is relatively immune to the vasoconstrictive effects. These findings suggest that the comparison of the ear and finger pulse oximeter wave forms might be used as a real-time monitor of sympathetic tone and that the ear plethysmography may be a suitable monitor of the systemic circulation.

Entities:  

Mesh:

Year:  2001        PMID: 11375830     DOI: 10.1097/00000539-200106000-00026

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  26 in total

1.  Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: time domain analysis.

Authors:  Aymen A Alian; Nicholas J Galante; Nina S Stachenfeld; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2011-11-04       Impact factor: 2.502

Review 2.  Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Claudio Sandroni; Fabio Cavallaro; Cristina Marano; Chiara Falcone; Paolo De Santis; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2012-06-26       Impact factor: 17.440

3.  Analysis of the ear pulse oximeter waveform.

Authors:  Aymen A Awad; Robert G Stout; M Ashraf M Ghobashy; Hoda A Rezkanna; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2006-04-13       Impact factor: 2.502

4.  Using the morphology of photoplethysmogram peaks to detect changes in posture.

Authors:  Stephen P Linder; Suzanne M Wendelken; Edward Wei; Susan P McGrath
Journal:  J Clin Monit Comput       Date:  2006-05-11       Impact factor: 2.502

5.  Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform.

Authors:  Michael J Gesquiere; Aymen A Awad; David G Silverman; Robert G Stout; Denis H Jablonka; Tyler J Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

6.  Monitoring of cardiovascular reactivity to cold stress using digital volume pulse characteristics in health and diabetes.

Authors:  Ashok K Jaryal; Nandakumar Selvaraj; Jayashree Santhosh; Sneh Anand; Kishore K Deepak
Journal:  J Clin Monit Comput       Date:  2009-03-24       Impact factor: 2.502

7.  Smartphone applications (apps) for heart rate measurement in children: comparison with electrocardiography monitor.

Authors:  Chi-Lin Ho; Yun-Ching Fu; Ming-Chih Lin; Sheng-Ching Chan; Betau Hwang; Sheng-Ling Jan
Journal:  Pediatr Cardiol       Date:  2013-11-21       Impact factor: 1.655

8.  Impact of skin incision on the pleth variability index.

Authors:  Masaharu Takeyama; Akira Matsunaga; Yasuyuki Kakihana; Mina Masuda; Tamotsu Kuniyoshi; Yuichi Kanmura
Journal:  J Clin Monit Comput       Date:  2011-09-18       Impact factor: 2.502

9.  Respiratory variations in the photoplethysmographic waveform amplitude depend on type of pulse oximetry device.

Authors:  Lars Øivind Høiseth; Ingrid Elise Hoff; Ove Andreas Hagen; Knut Arvid Kirkebøen; Svein Aslak Landsverk
Journal:  J Clin Monit Comput       Date:  2015-06-12       Impact factor: 2.502

10.  Contribution of systemic vascular reactivity to variability in pulse volume amplitude response during reactive hyperemia.

Authors:  Geetanjali Bade; Dinu S Chandran; Ashok Kumar Jaryal; Anjana Talwar; Kishore Kumar Deepak
Journal:  Eur J Appl Physiol       Date:  2019-01-14       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.