Literature DB >> 11372943

Extramedullary fixation of 569 unstable intertrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems.

K Lunsjö1, L Ceder, K G Thorngren, B Skytting, J Tidermark, P O Berntson, I Allvin, S Norberg, K Hjalmars, S Larsson, R Knebel, A Hauggaard, L Stigsson.   

Abstract

We compared the efficacy of the Medoff sliding plate (MSP) with 3 other screw-plate systems for fixation of unstable intertrochanteric fractures in a randomized multicenter trial of 569 elderly patients. The MSP has biaxial dynamic capacity along both the neck and the shaft of the femur unlike the other systems, which lack dynamic capacity along the shaft. 268 fractures were operated on with the MSP, and 301 with the dynamic hip screw (DHS), with or without a trochanteric stabilizing plate (DHS/TSP) or with the dynamic condylar screw (DCS). The MSP had recently been shown to the surgeons. The patients in the groups were similar as regards age, domestic situation, preinjury walking ability and type of fracture. We followed the patients clinically and radiographically for at least 1 year. There was no significant difference in walking ability at follow-up or rate of return to home. Fixation failure occurred in 18/268 fractures operated on with the MSP, in 8/238 with the DHS, in 3/49 with the DHS/TSP and in 1/14 with the DCS. The difference in the rate of fixation failure was not statistically significant when the MSP group was compared to the 3 other groups. In 14 of the 18 fixation failures in the MSP group, the biaxial dynamic capacity of the MSP had not been used due to technical errors by surgeons, unfamiliar with the new method. No selection bias was found regarding fracture types in the 2 subgroups of patients with correct or inadequate biaxial dynamization. Extramedullary fixation of unstable intertrochanteric fractures with these implants showed a low failure rate. When using the MSP, biaxial dynamization must be correctly performed.

Entities:  

Mesh:

Year:  2001        PMID: 11372943     DOI: 10.1080/000164701317323372

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  8 in total

Review 1.  Intertrochanteric fractures: a review of fixation methods.

Authors:  Senthil Nathan Sambandam; Jayadev Chandrasekharan; Varatharaj Mounasamy; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-30

Review 2.  Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis.

Authors:  Sharon R Lewis; Richard Macey; Joseph Lewis; Jamie Stokes; James R Gill; Jonathan A Cook; William Gp Eardley; Martyn J Parker; Xavier L Griffin
Journal:  Cochrane Database Syst Rev       Date:  2022-02-10

Review 3.  Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.

Authors:  Martyn J Parker; Avishek Das
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28

Review 4.  Influence of osteoporosis on fracture fixation--a systematic literature review.

Authors:  J Goldhahn; N Suhm; S Goldhahn; M Blauth; B Hanson
Journal:  Osteoporos Int       Date:  2008-06       Impact factor: 4.507

5.  Treatment of subtrochanteric femoral fractures using Selfdynamisable internal fixator.

Authors:  Ivan D Micic; Milorad B Mitkovic; Il-Hyung Park; Desimir B Mladenovic; Predrag M Stojiljkovic; Zoran B Golubovic; In-Ho Jeon
Journal:  Clin Orthop Surg       Date:  2010-11-05

6.  Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

Authors:  Johnny Paulsson; Josefine Corin Stig; Ola Olsson
Journal:  BMC Musculoskelet Disord       Date:  2017-08-24       Impact factor: 2.362

Review 7.  Internal fixation treatments for intertrochanteric fracture: a systematic review and meta-analysis of randomized evidence.

Authors:  Jiajie Yu; Chao Zhang; Ling Li; Joey S W Kwong; Li Xue; Xiantao Zeng; Li Tang; Youping Li; Xin Sun
Journal:  Sci Rep       Date:  2015-12-11       Impact factor: 4.379

Review 8.  Trochanteric stabilizing plate in the treatment of trochanteric fractures: a scoping review.

Authors:  Carl Erik Alm; Jan-Erik Gjertsen; Trude Basso; Kjell Matre; Stephan Rörhl; Jan Erik Madsen; Frede Frihagen
Journal:  Acta Orthop       Date:  2021-07-23       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.