Literature DB >> 11372540

Reproducibility of scanning laser polarimetry (GDx) of peripapillary retinal nerve fiber layer thickness in normal subjects.

M S Kook1, K Sung, R H Park, K R Kim, S T Kim, W Kang.   

Abstract

PURPOSE: To assess the reproducibility of measurement of retinal nerve fiber layer (RNFL) thickness among subjects using the GDx Nerve Fiber Analyzer (NFA).
METHODS: One eye of each of five young and healthy volunteers was imaged by three newly trained technicians (R.-H.P, K.-R.K., and S.-T.K.). Each volunteer was scanned six consecutive times for five independent times within a 1-month period. One composite image was selected out of three best images per session. Intra- and interoperator reproducibilities were calculated and the influence of placement of measurement ellipse by a single operator on interobserver reproducibility was also investigated.
RESULTS: Mean coefficients of variation for total integral value of RNFL were 3.67 +/- 1.47%, 3.86 +/- 2.13%, and 4.16 +/- 1.97%, respectively for the three technicians. Interoperator variability was not statistically significant (P = 0.075), and the difference was even less if a single ellipse drawn by one operator was used in all measurements (P = 0.1528) by repeated-measures analysis of variance (ANOVA).
CONCLUSIONS: The results suggest that GDx NFA may provide acceptable intraoperator as well as interoperator reproducibility among Asian eyes.

Entities:  

Mesh:

Year:  2001        PMID: 11372540     DOI: 10.1007/s004170000247

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  9 in total

Review 1.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

2.  Influence of optic disc size on parameters of retinal nerve fiber analysis with laser scanning polarimetry.

Authors:  Robert Laemmer; Folkert K Horn; Arne Viestenz; Anselm G Juenemann; Christian Y Mardin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-09-21       Impact factor: 3.117

3.  Corneal birefringence changes after laser assisted in situ keratomileusis and their influence on retinal nerve fibre layer thickness measurement by means of scanning laser polarimetry.

Authors:  M Centofanti; F Oddone; M Parravano; L Gualdi; M G Bucci; G Manni
Journal:  Br J Ophthalmol       Date:  2005-06       Impact factor: 4.638

4.  Imaging of the optic nerve and retinal nerve fiber layer: an essential part of glaucoma diagnosis and monitoring.

Authors:  Jacek Kotowski; Gadi Wollstein; Hiroshi Ishikawa; Joel S Schuman
Journal:  Surv Ophthalmol       Date:  2013-10-16       Impact factor: 6.048

5.  The relationship between optical coherence tomography and scanning laser polarimetry measurements in glaucoma.

Authors:  Yun Suk Chung; Yong Ho Sohn
Journal:  Korean J Ophthalmol       Date:  2006-12

6.  Assessment of the retinal nerve fiber layer of the normal and glaucomatous monkey with scanning laser polarimetry.

Authors:  Robert N Weinreb; Christopher Bowd; Linda M Zangwill
Journal:  Trans Am Ophthalmol Soc       Date:  2002

Review 7.  [Glaucoma diagnosis using scanning laser polarimetry].

Authors:  E M Hoffmann; A Schulze
Journal:  Ophthalmologe       Date:  2009-08       Impact factor: 1.059

8.  Effect of posterior capsular opacification removal on scanning laser polarimetry measurements.

Authors:  José Javier García-Medina; Manuel García-Medina; Samuel González-Ocampo Dorta; María Dolores Pinazo-Durán; Roberto Gallego-Pinazo; Vicente Calixto Zanón-Moreno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-03-22       Impact factor: 3.117

9.  Structural and functional relationships in glaucoma using standard automated perimetry and the Humphrey Matrix.

Authors:  Seong Bae Park; Yoon Pyo Nam; Kyung Rim Sung; Michael S Kook
Journal:  Korean J Ophthalmol       Date:  2009-09-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.