Validation of DIAGNOdent for quantification of smooth-surface caries: an in vitro study.

X Q Shi1, S Tranaeus, B Angmar-Månsson.   

Abstract

The aims were 1) to validate a laser-based device, KaVo DIAGNOdent, for quantification of caries lesions on smooth surfaces, using histopathologic and microradiographic analyses as the gold standard, and 2) to test inter- and intra-observer agreements. We also investigated the influence on DIAGNOdent readings of the storage medium used for extracted teeth. Two observers measured independently the tooth surfaces of 40 extracted premolars that had been stored in thymol-saturated saline. After subsequent storage in neutral-buffered formalin for 14 days they were re-measured. The teeth were then sectioned for histopathologic and microradiographic analysis. The Spearman rank correlation coefficients between lesion depth and DIAGNOdent readings were 0.78-0.83 and 0.85 for teeth stored in thymol-saturated saline and formalin, respectively. Inter- and intra-observer agreements were 0.94 and 0.95 when the teeth were stored in thymol-saturated saline. The DIAGNOdent reading was almost 1.5 times higher for teeth stored in formalin than for those stored in thymol saline. The Spearman rank correlation coefficient between mineral loss in enamel (deltaZ) and DIAGNOdent readings ranged from 0.64 to 0.68. It was concluded that DIAGNOdent may be helpful for assessing smooth-surface caries, but the cut-off points need to be assessed under clinical conditions. The increase in fluorescence associated with storage of teeth in formalin warrants further investigation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11370753     DOI: 10.1080/000163501750157153

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  21 in total

1.  Relationship between laser fluorescence and bacterial invasion in arrested dentinal carious lesions.

Authors:  Yukiteru Iwami; Hiroko Yamamoto; Mikako Hayashi; Shigeyuki Ebisu
Journal:  Lasers Med Sci       Date:  2010-06-10       Impact factor: 3.161

2.  A novel LED-based device for occlusal caries detection.

Authors:  Ali Murat Aktan; Mehmet Ata Cebe; Mehmet Ertuğrul Ciftçi; Emine Sirin Karaarslan
Journal:  Lasers Med Sci       Date:  2011-11-13       Impact factor: 3.161

3.  Inhibition of enamel lesion formation by fluoridated milk assessed by laser fluorescence--an in vitro study.

Authors:  K Engström; L G Petersson; S Twetman
Journal:  Clin Oral Investig       Date:  2006-05-16       Impact factor: 3.573

4.  Evaluation of laser fluorescence in monitoring non-cavitated caries lesion progression on smooth surfaces in vitro.

Authors:  J A Rodrigues; C S Sarti; C M Assunção; R A Arthur; A Lussi; M B Diniz
Journal:  Lasers Med Sci       Date:  2017-07-02       Impact factor: 3.161

5.  The possibility of digital imaging in the diagnosis of occlusal caries.

Authors:  Sachi Umemori; Ken-Ichi Tonami; Hiroshi Nitta; Shiro Mataki; Kouji Araki
Journal:  Int J Dent       Date:  2010-03-07

6.  An in vitro comparison of different diagnostic methods in detection of residual dentinal caries.

Authors:  Nimet Unlu; Rabia Banu Ermis; Sevgi Sener; Ebru Kucukyilmaz; Ali Riza Cetin
Journal:  Int J Dent       Date:  2010-06-03

7.  In situ and in vitro comparison of laser fluorescence with visual inspection in detecting occlusal caries lesions.

Authors:  Andréia Bolzan de Paula; Juliana Alvares Duarte Bonini Campos; Michele Baffi Diniz; Josimeri Hebling; Jonas Almeida Rodrigues
Journal:  Lasers Med Sci       Date:  2009-09-26       Impact factor: 3.161

8.  The efficacy of the use of IR laser phototherapy associated to biphasic ceramic graft and guided bone regeneration on surgical fractures treated with wire osteosynthesis: a comparative laser fluorescence and Raman spectral study on rabbits.

Authors:  Antônio Luiz Barbosa Pinheiro; Nicole Ribeiro Silva Santos; Priscila Chagas Oliveira; Gilberth Tadeu Santos Aciole; Thais Andrade Ramos; Tayná Assunção Gonzalez; Laís Nogueira da Silva; Artur Felipe Santos Barbosa; Landulfo Silveira
Journal:  Lasers Med Sci       Date:  2012-07-26       Impact factor: 3.161

9.  In vitro comparison of laser fluorescence performance with visual examination for detection of occlusal caries in permanent and primary molars.

Authors:  Jonas A Rodrigues; Michele B Diniz; Erika B Josgrilberg; Rita C L Cordeiro
Journal:  Lasers Med Sci       Date:  2008-03-29       Impact factor: 3.161

10.  Clinical diagnosis of fissure caries with conventional and laser-induced fluorescence techniques.

Authors:  C H Chu; E C M Lo; D S H You
Journal:  Lasers Med Sci       Date:  2009-03-04       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.