| Literature DB >> 11370377 |
Abstract
A new electronic design for continuous motional series resonant frequency monitoring of loaded quartz crystal resonators is presented. Using this circuit, a low-cost method for a simple determination of equivalent circuit parameters of quartz crystal resonators is described. Measurements made with the proposed system on typical AT cut quartz crystals are in good agreement with those of an Impedance Analyzer.Year: 2001 PMID: 11370377 DOI: 10.1109/58.911746
Source DB: PubMed Journal: IEEE Trans Ultrason Ferroelectr Freq Control ISSN: 0885-3010 Impact factor: 2.725