The influence of roughness, angle, range, and transducer type on the echo signal from planar interfaces.

J E Wilhjelm1, P C Pedersen, S M Jacobsen.   

Abstract

The received electrical echo signal from a pulse-echo system insonifying a planar interface was measured for varying degrees of rms roughness [0 to 0.29 mm (0 to 1.7 lambda)], angles of incidence, theta, (-7 degrees to 7 degrees), and ranges to a planar or focused transducer. The effect of varying theta is quantified in terms of the energy of the received signal, E(theta), and the normalized spectrum of the received signal. E(theta) is approximately Gaussian when using a planar transducer or a focused transducer with the reflecting interface located at or beyond the focal point. For focused transducers with the interface located closer than the geometrical point of focus, two maxima can sometimes be observed when varying the incident angle. As is generally known, the width of E(theta) is strongly dependent on transducer type, e.g., for a smooth interface, the -3 dB width for a 25.4 mm diameter 5-MHz planar and focused transducer was approximately 0.5 degree and 4 degrees (at the focal point), respectively. E(0 degree) as a function of surface roughness, Rq, was nearly linear on a decibel scale, with a slope of -109 dB/(Rq/lambda) and -61 dB/(Rq/lambda) for planar and focused transducers, respectively. The characteristic nulls present in the normalized spectra of the echo signal at non-normal incidence tend to vanish with increasing Rq when using planar transducers. For focused transducers, the normalized spectra change from relatively flat to monotonically decreasing as Rq increases, and they exhibit reduced amplitude with increased incident angle.

Entities:  

Mesh:

Year:  2001        PMID: 11370365     DOI: 10.1109/58.911734

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

1.  Improved imaging of the carotid artery in the short-axis plane by a mechanical scanning ultrasonic probe.

Authors:  Kazuki Kudo; Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2007-03-15       Impact factor: 1.314

2.  Thoracic scales of moths as a stealth coating against bat biosonar.

Authors:  Thomas R Neil; Zhiyuan Shen; Daniel Robert; Bruce W Drinkwater; Marc W Holderied
Journal:  J R Soc Interface       Date:  2020-02-26       Impact factor: 4.118

3.  Surface roughness detection of arteries via texture analysis of ultrasound images for early diagnosis of atherosclerosis.

Authors:  Lili Niu; Ming Qian; Wei Yang; Long Meng; Yang Xiao; Kelvin K L Wong; Derek Abbott; Xin Liu; Hairong Zheng
Journal:  PLoS One       Date:  2013-10-17       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.