We studied the difference in glucose levels between capillary and venous whole blood during 75-g oral glucose tolerance test (OGTT) in 75 healthy subjects. Capillary and venous whole blood glucose values were measured by HK-G6PD method after deproteinization. The post-loaded glucose levels in capillary blood were significantly higher than those in venous blood, and the mean values of capillary and venous difference at 30, 60, 90, 120 and 180 min were 1.37, 1.40, 1.07, 0.95 and 0.52 mmol/l, respectively, with the maximum difference at 60 min. No correlation was found in the magnitude of the differences in glucose between capillary and venous blood specimens. We determined the inaccuracy of six self-monitoring blood glucose devices relative to the reference method using venous plasma, venous whole blood and capillary whole blood from 31 diabetic patients. The differences of mean values of venous whole blood and capillary whole blood, and venous whole blood and venous plasma, and capillary whole blood and venous plasma were 9.6%, 11.3% and -3.2%, respectively. The range of bias and Sy/x were 0.31-1.06 mmol/l and 0.71-1.07 mmol/l, respectively, compared to the reference method using venous plasma.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11369356     DOI: 10.1016/s0009-8981(01)00426-0

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  26 in total

1.  Two hour blood glucose levels in at-risk babies: An audit of Canadian guidelines.

Authors:  Jennifer Croke; Meagan Sullivan; Anne Ryan-Drover; Ed Randell; Wayne Andrews; Khalid Aziz
Journal:  Paediatr Child Health       Date:  2009-04       Impact factor: 2.253

2.  Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference.

Authors:  Mervi Andelin; Jort Kropff; Viktorija Matuleviciene; Jeffrey I Joseph; Stig Attvall; Elvar Theodorsson; Irl B Hirsch; Henrik Imberg; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; J Hans DeVries; Marcus Lind
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

3.  Comparison of Accuracy Guidelines for Hospital Glucose Meters.

Authors:  Cynthia Foss Bowman; James H Nichols
Journal:  J Diabetes Sci Technol       Date:  2020-01-25

4.  Screening guidelines for newborns at risk for low blood glucose.

Authors: 
Journal:  Paediatr Child Health       Date:  2004-12       Impact factor: 2.253

5.  Analysis of the Indian Council of Medical Research-India Diabetes (ICMR-INDIAB) study.

Authors:  K M Venkat Narayan; Justin B Echouffo-Tcheugui
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

Review 6.  The screening and management of newborns at risk for low blood glucose.

Authors:  Michael R Narvey; Seth D Marks
Journal:  Paediatr Child Health       Date:  2019-12-09       Impact factor: 2.253

Review 7.  Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.

Authors:  Jeffrey I Joseph; Marc C Torjman; Paul J Strasma
Journal:  J Diabetes Sci Technol       Date:  2015-06-15

8.  Comparison of venous plasma glycemia and capillary glycemia for the screening of type 2 diabetes mellitus in the Japanese-Brazilian community of Mombuca (Guatapará-SP).

Authors:  Maria Cristina Foss-Freitas; Regina C G de Andrade; Roberta C Figueiredo; Ana Emília Pace; Edson Z Martinez; Amaury L Dal Fabro; Laércio J Franco; Milton C Foss
Journal:  Diabetol Metab Syndr       Date:  2010-01-22       Impact factor: 3.320

9.  Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Authors:  Arjunan Ganesh; Brian Hipszer; Navdeep Loomba; Barbara Simon; Marc C Torjman; Jeffrey Joseph
Journal:  J Diabetes Sci Technol       Date:  2008-03

10.  A comparison of ex vivo cytokine production in venous and capillary blood.

Authors:  M Eriksson; E Sartono; C L Martins; C Balé; M-L Garly; H Whittle; P Aaby; B K Pedersen; M Yazdanbakhsh; C Erikstrup; C S Benn
Journal:  Clin Exp Immunol       Date:  2007-10-09       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.