Literature DB >> 11369334

Update on value of the anion gap in clinical diagnosis and laboratory evaluation.

P H Lolekha1, S Vanavanan, S Lolekha.   

Abstract

Anion gap (AG) is a calculated value commonly used in clinical practice. It approximates the difference between the concentration of unmeasured anions (UA) and unmeasured cations (UC) in serum. At present, the reference range of anion gap has been lowered from 8-16 to 3-11 mmol/l because of the changes in technique for measuring electrolyte. However, clinicians and textbooks still refer and use the old reference value of 8-16 mmol/l. This may lead to misinterpretation of the value of anion gap. Our study updated the value of anion gap in clinical diagnosis and laboratory evaluation. Criteria for using anion gap were also suggested. We analyzed serum electrolyte using the Beckman Synchron CX5. The anion gap was calculated from the formula: [Na(+)-(Cl(-)+HCO(3)(-))]. We estimated the reference range using the non-parametric percentile estimation method. The reference range of anion gap obtained from 124 healthy volunteers was 5-12 mmol/l, which was low and confirmed the reports from other studies (3-11 mmol/l) using ion-selective electrode. From the retrospective study on the 6868 sets of serum electrolyte among hospitalized patients, we found the incidences of normal, increased, and decreased anion gaps were 59.5%, 37.6%, and 2.9%, respectively. The mean and central 90% range of increased anion gap were 16 and 13-20 mmol/l, which was lower than those reported in previous study (25 and 19-28 mmol/l). Anion gap exceeding 24 mmol/l was rare. The mean and central 90% range of decreased anion gap were 3 and 2-4 mmol/l, which were lower than those reported in previous study (6 and 3-8 mmol/l). The value of less than 2 mmol/l was rare. The most common causes of increased anion gap (hypertensive disease, chronic renal failure, malignant neoplasms, diabetes mellitus and heart diseases) and decreased anion gap (liver cirrhosis and nephrotic syndrome) in this study were similar to those in previous studies. We found two cases of IgG multiple myeloma with anion gap of 2 mmol/l. In conclusion, clinicians and laboratorians can use the anion gap as clue in quality control. They can check the incidences of increased and decreased anion gap. If one finds high incidence of increased anion gap (>24 mmol/l) or decreased anion gap (<2 mmol/l), one should check the quality control of electrolyte and whether the patients were hypoalbuminemia or hyperglobulinemia. An anion gap exceeding 24 mmol/l will suggest the presence of metabolic acidosis. It is very rare to find anion gap with the negative sign.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11369334     DOI: 10.1016/s0009-8981(01)00459-4

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  13 in total

1.  Parameters in defining acid-base disorders.

Authors:  Kenrick Berend
Journal:  Intern Emerg Med       Date:  2010-04-22       Impact factor: 3.397

Review 2.  The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved?

Authors:  Jeffrey A Kraut; Glenn T Nagami
Journal:  Clin J Am Soc Nephrol       Date:  2013-07-05       Impact factor: 8.237

3.  Prevalence and complications of chronic kidney disease in a representative elderly population in Iceland.

Authors:  Aghogho Okparavero; Meredith C Foster; Hocine Tighiouart; Vilmundur Gudnason; Olafur Indridason; Hrefna Gudmundsdottir; Gudny Eiriksdottir; Elias F Gudmundsson; Lesley A Inker; Andrew S Levey
Journal:  Nephrol Dial Transplant       Date:  2015-10-31       Impact factor: 5.992

4.  Characterisation of metabolic acidosis in Kenyan children admitted to hospital for acute non-surgical conditions.

Authors:  P Sasi; M English; J Berkley; B Lowe; M Shebe; R Mwakesi; G Kokwaro
Journal:  Trans R Soc Trop Med Hyg       Date:  2005-10-27       Impact factor: 2.184

5.  Severe metabolic alkalosis due to the combination of unmeasured cations and hypochloraemia in a patient with gastroparesia and frequent emesis.

Authors:  Alexandre Toledo Maciel
Journal:  BMJ Case Rep       Date:  2009-05-18

6.  Defining the late implementation of extracorporeal membrane oxygenation (ECMO) by identifying increased mortality risk using specific physiologic cut-points in neonatal and pediatric respiratory patients.

Authors:  Gary Grist; Carrie Whittaker; Kellie Merrigan; Jason Fenton; Eugenia Pallotto; Gary Lofland
Journal:  J Extra Corpor Technol       Date:  2009-12

7.  Predictors of acute metabolic decompensation in children with maple syrup urine disease at the emergency department.

Authors:  Yılmaz Yıldız; Leman Akcan Yıldız; Ali Dursun; Ayşegül Tokatlı; Turgay Coşkun; Özlem Tekşam; Hatice Serap Sivri
Journal:  Eur J Pediatr       Date:  2020-02-11       Impact factor: 3.183

Review 8.  Hyperphosphatemia, a Cause of High Anion Gap Metabolic Acidosis: Report of a Case and Review of the Literature.

Authors:  Seyed Ali Sadjadi; Alexander Pi
Journal:  Am J Case Rep       Date:  2017-04-28

9.  Ion-selective electrode and anion gap range: What should the anion gap be?

Authors:  Seyed-Ali Sadjadi; Rendell Manalo; Navin Jaipaul; James McMillan
Journal:  Int J Nephrol Renovasc Dis       Date:  2013-06-07

10.  The serum anion gap is associated with disease severity and all-cause mortality in coronary artery disease.

Authors:  Shi-Wei Yang; Yu-Jie Zhou; Ying-Xin Zhao; Yu-Yang Liu; Xiao-Fang Tian; Zhi-Jian Wang; De-An Jia; Hong-Ya Han; Bin Hu; Hua Shen; Fei Gao; Lu-Ya Wang; Jie Lin; Guo-Zhong Pan; Jian Zhang; Zhen-Feng Guo; Jie Du; Da-Yi Hu
Journal:  J Geriatr Cardiol       Date:  2017-06       Impact factor: 3.327

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.