Literature DB >> 11361310

Effect of magnetic insoles on postural sway measures in men and women during a static balance test.

R Suomi1, D M Koceja.   

Abstract

Numerous anecdotal reports have suggested a growing public enthusiasm for magnetic devices for treatment of pain and various motor and sensory dysfunctions. Although the principles behind magnetic therapy are well documented, a complete technical explanation of whether static magnet application is effective is lacking due to a paucity of scientific research. In this study the effectiveness of magnetic insoles on postural sway measures during a single application were investigated. Twenty-eight adults (14 old, 14 young) were assessed on postural sway measures while performing a static two-legged stance test on a Kistler force platform under two treatment conditions (magnetic insoles, nonmagnetic insoles). Significant reductions in total sway area and lateral sway scores were obtained by the older adults while standing on the magnetic insoles. These preliminary results indicate that treatment of postural instability using magnetic insoles may be a viable alternative for older adults.

Entities:  

Mesh:

Year:  2001        PMID: 11361310     DOI: 10.2466/pms.2001.92.2.469

Source DB:  PubMed          Journal:  Percept Mot Skills        ISSN: 0031-5125


  5 in total

1.  Magnet therapy.

Authors:  Leonard Finegold; Bruce L Flamm
Journal:  BMJ       Date:  2006-01-07

2.  Effectiveness of a heel cup with an arch support insole on the standing balance of the elderly.

Authors:  Tzu-Hsuan Chen; Li-Wei Chou; Mei-Wun Tsai; Ming-Jor Lo; Mu-Jung Kao
Journal:  Clin Interv Aging       Date:  2014-02-20       Impact factor: 4.458

3.  The effect of flat and textured insoles on the balance of primary care elderly people: a randomized controlled clinical trial.

Authors:  Cecília de Morais Barbosa; Manoel Barros Bértolo; Juliana Zonzini Gaino; Michael Davitt; Zoraida Sachetto; Eduardo de Paiva Magalhães
Journal:  Clin Interv Aging       Date:  2018-02-19       Impact factor: 4.458

4.  Static magnetic field therapy: a critical review of treatment parameters.

Authors:  Agatha P Colbert; Helané Wahbeh; Noelle Harling; Erin Connelly; Heather C Schiffke; Cora Forsten; William L Gregory; Marko S Markov; James J Souder; Patricia Elmer; Valerie King
Journal:  Evid Based Complement Alternat Med       Date:  2007-10-04       Impact factor: 2.629

5.  Effect of Insoles with a Toe-Grip Bar on Toe Function and Standing Balance in Healthy Young Women: A Randomized Controlled Trial.

Authors:  Hideki Nakano; Shin Murata; Teppei Abiko; Masashi Sakamoto; Dai Matsuo; Michio Kawaguchi; Youji Sugo; Hiroaki Matsui
Journal:  Rehabil Res Pract       Date:  2017-11-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.