Literature DB >> 11359488

Hair removal using a long-pulsed Nd:YAG Laser: comparison at fluences of 50, 80, and 100 J/cm.

D J Goldberg1, S Silapunt.   

Abstract

BACKGROUND: Unwanted hair is a widespread cosmetic problem. Many temporary methods of hair removal have proved unsatisfactory. A variety of laser systems with varying wavelengths, pulse durations, and energy fluences are currently utilized for hair removal. Optimal laser parameters continue to require further investigation.
OBJECTIVE: To evaluate the efficacy and safety of a long-pulse millisecond Nd:YAG hair removal laser utilizing fluences of either 50, 80, or 100 J/cm2.
METHODS: Fifteen subjects were treated with a contact cooled 50 msec Nd:YAG laser at fluences 30, 50, or 100 J/cm2. Reduction in hair regrowth was measured at 3 months after treatment by comparing the terminal hair count to the baseline values. Potential complications were also evaluated.
RESULTS: Average hair reduction at 3 months after treatment was 29%, 29%, and 27% in areas treated with a 50-msec Nd:YAG laser at fluences of 50, 80, and 100 J/cm2, respectively. Although short-term blistering was noted in two subjects, no hyperpimentation, hypopigmentation, or scarring was observed at 3 months after treatment.
CONCLUSION: Long-pulse millisecond Nd:YAG laser hair removal with fluences of either 50, 80, or 100 J/cm2 leads to similar efficacy with no significant adverse effects.

Entities:  

Mesh:

Year:  2001        PMID: 11359488     DOI: 10.1046/j.1524-4725.2001.00329.x

Source DB:  PubMed          Journal:  Dermatol Surg        ISSN: 1076-0512            Impact factor:   3.398


  6 in total

1.  Meta-analysis of hair removal laser trials.

Authors:  Afshin Sadighha; Golnaz Mohaghegh Zahed
Journal:  Lasers Med Sci       Date:  2007-11-20       Impact factor: 3.161

2.  Optimizing treatment parameters for hair removal using long-pulsed Nd:YAG-lasers.

Authors:  K Raff; M Landthaler; U Hohenleutner
Journal:  Lasers Med Sci       Date:  2004-02-24       Impact factor: 3.161

3.  Comparative study of the clinico-trichoscopic response to treatment of hirsutism with long pulsed (1064 nm) Nd:YAG laser in idiopathic hirsutism and polycystic ovarian syndrome patients.

Authors:  Nahida Nabi; Yasmeen Jabeen Bhat; Uzair Khursheed Dar; Aijaz Hakeem; Shahnaz A Mir; Iffat Hassan Shah; Mohd Rafiq Tilwani
Journal:  Lasers Med Sci       Date:  2021-03-25       Impact factor: 3.161

4.  Comparative Study of Diode Laser Versus Neodymium-Yttrium Aluminum: Garnet Laser Versus Intense Pulsed Light for the Treatment of Hirsutism.

Authors:  Neerja Puri
Journal:  J Cutan Aesthet Surg       Date:  2015 Apr-Jun

Review 5.  The role of lasers and intense pulsed light technology in dermatology.

Authors:  Zain Husain; Tina S Alster
Journal:  Clin Cosmet Investig Dermatol       Date:  2016-02-04

6.  Long-pulsed Nd: YAG Laser and Intense Pulse Light-755 nm for Idiopathic Facial Hirsutism: A Comparative Study.

Authors:  Arpit Shrimal; Souvik Sardar; Soumyajit Roychoudhury; Somenath Sarkar
Journal:  J Cutan Aesthet Surg       Date:  2017 Jan-Mar
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.