Literature DB >> 11359482

Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients Part II: An up to 15-years radiographic evaluation.

I E Naert1, J A Duyck, M M Hosny, M Quirynen, D van Steenberghe.   

Abstract

A total of 123 patients were followed between January 1983 and July 1998 with 140 tooth-implant connected prostheses. The age of the patients at prosthesis installation ranged from 20 to 79 years (mean 51.8). 339 (Brånemark(R) system) implants were connected to 313 teeth. The loading time ranged from 1.5 to 15 years (mean: 6.5). 123 patients were randomly selected as a control group with freestanding implant-supported prostheses only. The age of the patients at prosthesis installation ranged from 22 to 78 years (mean 52.3). The loading time for the 329 freestanding (Brånemark(R) system) implants ranged from 1.3 to 14.5 years (mean: 6.2). Evolution of the marginal bone stability around the implant in the tooth-implant connected as well as the freestanding group was studied with respect to the prognosis of the implants. Over the period from 0 to 15 years, there was significantly more marginal bone loss (0.7 mm) in tooth-implant connected versus freestanding prostheses. No significant difference in marginal bone loss was found between the non-rigid tooth-implant connected prostheses versus freestanding prostheses. However, there was a significant difference in marginal bone loss for rigid and multi-connected tooth-implant connected prostheses versus freestanding ones. The results of this study indicate that more bone is lost around implants which are rigidly connected to teeth. This suggests that bending load, which is increased in tooth-implant connected prostheses, might be responsible for this phenomenon. These observations favor the use of freestanding prostheses whenever possible. However, the clinical significance of greater bone loss in rigid versus non-rigid connections might outweigh the annoying phenomenon of tooth intrusion in the case of non-rigid tooth connection, when connection is considered.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11359482     DOI: 10.1034/j.1600-0501.2001.012003245.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  9 in total

1.  Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result.

Authors:  Florian Beuer; Caroline Sachs; Julian Groesser; Jan-Frederik Gueth; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2015-09-24       Impact factor: 3.573

2.  Rehabilitation of a gunshot wound with dental implants.

Authors:  M C Sharma; M M Swamy
Journal:  Med J Armed Forces India       Date:  2012-09-14

3.  Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring.

Authors:  Shao-Fu Huang; Wan-Rung Chen; Chun-Li Lin
Journal:  Biomed Eng Online       Date:  2016-02-24       Impact factor: 2.819

Review 4.  The Overall Survival, Complication-Free Survival, and Related Complications of Combined Tooth-Implant Fixed Partial Dentures: A Literature Review.

Authors:  Peter Borg; James Puryer; Lisa McNally; Dominic O'Sullivan
Journal:  Dent J (Basel)       Date:  2016-05-25

Review 5.  Combined Implant and Tooth Support: An Up-to-Date Comprehensive Overview.

Authors:  Mahmoud K Al-Omiri; Maher Al-Masri; Mohannad M Alhijawi; Edward Lynch
Journal:  Int J Dent       Date:  2017-03-23

6.  Investigating the Effect of Nonrigid Connectors on the Success of Tooth-and-Implant-Supported Fixed Partial Prostheses in Maxillary Anterior Region: A Finite Element Analysis (FEA).

Authors:  Ramin Mosharraf; Paria Molaei; Amirhossein Fathi; Sabire Isler
Journal:  Int J Dent       Date:  2021-11-12

7.  Biomechanical considerations on tooth-implant supported fixed partial dentures.

Authors:  Konstantinos X Michalakis; Pasquale Calvani; Hiroshi Hirayama
Journal:  J Dent Biomech       Date:  2012-10-29

8.  Efficacy of adding a supporting implant in stress distribution of long-span fixed partial dentures: a 3D finite element analysis.

Authors:  Rami Shurbaji Mozayek; Mirza Allaf; Mohammad B Abuharb
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-06-15

9.  The effectiveness of adding a supporting implant in stress distribution of long span fixed partial denture (three-dimensional finite element analysis).

Authors:  Rami Shurbaji Mozayek; Mohammad Yamen Shurbaji Mozayek; Mirza Allaf; Mohammad Bassam Abouharb
Journal:  J Indian Prosthodont Soc       Date:  2016 Jul-Sep
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.