Bone response to implant-supported frameworks with differing degrees of misfit preload: in vivo study in rabbits.

T Jemt1, U Lekholm, C B Johansson.   

Abstract

PURPOSE: To study the bone response around implants placed in tibia of rabbits that supported misfitting superstructures secured with different degrees of preload.
MATERIALS AND METHODS: Twelve rabbits were provided with two terminal 10-mm and one intermediate 7-mm-long implant in each tibia. After an integration time of about 9 weeks, nine of the animals received one control framework each (n = 9), designed with good fit to all three implants. In the other tibia of these animals, and in both tibias in the remaining three rabbits, test frameworks (n = 15) were connected with a vertical misfit of about 1 mm to the intermediate implant. The intermediate set screws were tightened with a torque ranging from 15 Ncm to 26 Ncm in the different test frameworks. The fascia and skin was then sutured back over the implants. After a loading period of 2 to 3 weeks, the animals were sacrificed, and histomorphometric measurements were made and correlated to the different levels of preload of the central implant.
RESULTS: The mean bone-to-metal contact for the three best consecutive threads of the central implant was 40% for both test and control sites (p > .05). Compared to the other regions of the implant thread, less bone-to-metal contact was found at the tip of the test implant threads in the low preload group (p < .05). However, the same relation was not observed in the high preload group. A significant correlation was observed between increasing degree of preload in the central screw joint and increasing bone-to-metal contact, most obviously noticed at the tip of the implant thread (p < .01).
CONCLUSIONS: Misfit stress levels of clinical magnitudes do not seem to jeopardize osseointegration per se. On the contrary, clinical levels of preload stress seem to significantly promote bone remodeling at the tip of the implant thread.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11359257     DOI: 10.1111/j.1708-8208.2000.tb00003.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  Lateral static overload on immediately restored implants decreases the osteocyte index in peri-implant bone: a secondary analysis of a pre-clinical study in dogs.

Authors:  Celson Domingos de Calais; Dimorvan Bordin; Adriano Piattelli; Giovanna Iezzi; Alexandre Negretto; Jamil A Shibli
Journal:  Clin Oral Investig       Date:  2020-11-05       Impact factor: 3.573

Review 2.  Animal models for periodontal regeneration and peri-implant responses.

Authors:  Alpdogan Kantarci; Hatice Hasturk; Thomas E Van Dyke
Journal:  Periodontol 2000       Date:  2015-06       Impact factor: 7.589

3.  Peri-implant bone tissues around retrieved human implants after time periods longer than 5 years: a retrospective histologic and histomorphometric evaluation of 8 cases.

Authors:  Giovanna Iezzi; Adriano Piattelli; Carlo Mangano; Jamil A Shibli; Giovanni Vantaggiato; Massimo Frosecchi; Claudio Di Chiara; Vittoria Perrotti
Journal:  Odontology       Date:  2012-08-28       Impact factor: 2.634

4.  Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study.

Authors:  Si-Hoon Jo; Kyoung-Il Kim; Jae-Min Seo; Kwang-Yeob Song; Ju-Mi Park; Seung-Geun Ahn
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

Review 5.  Implant Bio-mechanics for Successful Implant Therapy: A Systematic Review.

Authors:  Khaled Mosfer Alzahrani
Journal:  J Int Soc Prev Community Dent       Date:  2020-11-24

6.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26

7.  Examining trabecular morphology and chemical composition of peri-scaffold osseointegrated bone.

Authors:  Linwei Lyu; Shicai Yang; Ye Jing; Chunqiu Zhang; Jikun Wang
Journal:  J Orthop Surg Res       Date:  2020-09-14       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.