L M Malbouisson1, F Préteux, L Puybasset, P Grenier, P Coriat, J J Rouby. 1. Réanimation Chirurgicale Pierre Viars, Département d'Anesthésie-Réanimation, Hôpital de la Pitié-Salpêtrière, University of Pierre et Marie Curie Paris VI, 47-83 boulevard de l'Hôpital, 75013 Paris, France.
Abstract
OBJECTIVE: The in-vitro validation of a computed tomographic (CT) software specifically designed for quantifying the volume of water contained in the lung. DESIGN: An in-vitro, ex-vivo study. In 1993, a postmortem left pneumonectomy was performed in a patient who died from acute respiratory distress syndrome. The lung was fixed, inflated and dried according to a technique proposed by Markarian and Dailey in 1975 aimed at producing a lung specimen spongy in texture and suitable for radiography. MEASUREMENTS AND RESULTS: In 1999, 13 CT scans of this lung specimen were performed corresponding to different bronchial instillations of known volumes of water and albumin 4%. The different lung weights resulting from the successive bronchial instillations were calculated using a specially designed software, Lungview, adapted for CT measurements and compared with the actual lung weight measured by an electronic scale. The increase in lung weight measured by Lungview was closely correlated with the actual increase in lung weight resulting from bronchial instillation of water and albumin (y = 0.99x - 23, r = 1 for water and y = x - 17, r = 1 for albumin 4%) and the precision of the bias was 7 g for water and 3 g for albumin 4%. CONCLUSIONS: This study shows that the CT software Lungview accurately measured the volume of lung water present within an air-dried exsanguine human lung.
OBJECTIVE: The in-vitro validation of a computed tomographic (CT) software specifically designed for quantifying the volume of water contained in the lung. DESIGN: An in-vitro, ex-vivo study. In 1993, a postmortem left pneumonectomy was performed in a patient who died from acute respiratory distress syndrome. The lung was fixed, inflated and dried according to a technique proposed by Markarian and Dailey in 1975 aimed at producing a lung specimen spongy in texture and suitable for radiography. MEASUREMENTS AND RESULTS: In 1999, 13 CT scans of this lung specimen were performed corresponding to different bronchial instillations of known volumes of water and albumin 4%. The different lung weights resulting from the successive bronchial instillations were calculated using a specially designed software, Lungview, adapted for CT measurements and compared with the actual lung weight measured by an electronic scale. The increase in lung weight measured by Lungview was closely correlated with the actual increase in lung weight resulting from bronchial instillation of water and albumin (y = 0.99x - 23, r = 1 for water and y = x - 17, r = 1 for albumin 4%) and the precision of the bias was 7 g for water and 3 g for albumin 4%. CONCLUSIONS: This study shows that the CT software Lungview accurately measured the volume of lung water present within an air-dried exsanguinehuman lung.
Authors: Giacomo Baldi; Luna Gargani; Antonio Abramo; Luigia D'Errico; Davide Caramella; Eugenio Picano; Francesco Giunta; Francesco Forfori Journal: Intensive Care Med Date: 2012-09-28 Impact factor: 17.440
Authors: Thomas Lescot; Marie-Pierre Bonnet; Abederrezak Zouaoui; Jean-Charles Muller; Catalin Fetita; Pierre Coriat; Louis Puybasset Journal: Intensive Care Med Date: 2005-07-01 Impact factor: 17.440
Authors: Davide Chiumello; Antonella Marino; Matteo Brioni; Federica Menga; Irene Cigada; Marco Lazzerini; Maria C Andrisani; Pietro Biondetti; Bruno Cesana; Luciano Gattinoni Journal: Intensive Care Med Date: 2012-09-19 Impact factor: 17.440
Authors: Nicolò Patroniti; Giacomo Bellani; Annamaria Manfio; Elena Maggioni; Angela Giuffrida; Giuseppe Foti; Antonio Pesenti Journal: Intensive Care Med Date: 2004-01-09 Impact factor: 17.440
Authors: Bernd Saugel; Konstantin Holzapfel; Jens Stollfuss; Tibor Schuster; Veit Phillip; Caroline Schultheiss; Roland M Schmid; Wolfgang Huber Journal: Scand J Trauma Resusc Emerg Med Date: 2011-05-23 Impact factor: 2.953
Authors: Alessandro R C Martins; Aline M Ambrósio; Denise T Fantoni; Ana Carolina B C F Pinto; Lenin Arturo Villamizar-Martinez; João H N Soares; Denise A Otsuki; Luiz Marcelo S Malbouisson Journal: Front Vet Sci Date: 2022-04-01