Literature DB >> 11355092

Limitations of B-scan ultrasound for diagnosing fractures of the mandibular condyle and ramus.

R E Friedrich1, K Plambeck, S Bartel-Friedrich, M Giese, R Schmelzle.   

Abstract

The aim of this study was to analyse the applications and limitations of B-scan ultrasonography for diagnosing fractures of the mandibular condyle and ramus. Thirty-two patients with 39 radiologically proven fractures of the mandibular condyle and ramus were included in the study. The patients were examined with a 7.5 MHz small-part applicator. Five patients without fractures of the facial skeleton acted as controls. Normal sonoanatomical findings had been obtained for patients without mandibular fractures. B-scan ultrasonography enabled the experienced examiner to identify dislocated fractures of the mandibular ramus and the articular process in 67% of the fractures. The main disadvantage of ultrasonography was the inability of this technique to identify non-dislocated fractures. Because of its low sensitivity and specificity, B-scan ultrasonography does not provide an alternative to X-ray diagnosis of mandibular condyle and ramus fractures.

Entities:  

Mesh:

Year:  2001        PMID: 11355092     DOI: 10.1007/pl00010679

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  6 in total

Review 1.  Review on the applications of ultrasonography in dentomaxillofacial region.

Authors:  Şehrazat Evirgen; Kıvanç Kamburoğlu
Journal:  World J Radiol       Date:  2016-01-28

2.  Preauricular Swelling Mimicking a Tumour: Dissolution of Mandibular Capitulum Following Trauma in a 15-Year Old Child.

Authors:  Reinhard E Friedrich; Felix K Kohlrusch
Journal:  In Vivo       Date:  2020 May-Jun       Impact factor: 2.155

Review 3.  The applications of ultrasound, and ultrasonography in dentistry: a scoping review of the literature.

Authors:  Mohamed Elbarbary; Adam Sgro; Saber Khazaei; Michael Goldberg; Howard C Tenenbaum; Amir Azarpazhooh
Journal:  Clin Oral Investig       Date:  2022-01-14       Impact factor: 3.573

4.  Comparison of accuracy of computed tomography scan and ultrasonography in the diagnosis of mandibular fractures.

Authors:  Saeed Nezafati; Mohamadali Ghavimi; Reza Javadrashid; Sina Farhadi; Vahid Dehnad
Journal:  Dent Res J (Isfahan)       Date:  2020-05-23

5.  Comparison of ultrasonography with submentovertex films and computed tomography scan in the diagnosis of zygomatic arch fractures.

Authors:  S Nezafati; R Javadrashid; S Rad; S Akrami
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

Review 6.  Diagnostic Accuracy of Ultrasonography for the Assessment of Maxillofacial Fractures: A Meta-analysis.

Authors:  Srikanth Gadicherla; Kalyana-Chakravarthy Pentapati; Nasrullah Rustaqi; Anupam Singh; Komal Smriti
Journal:  J Int Soc Prev Community Dent       Date:  2021-09-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.