Literature DB >> 11352515

Somatosensory evoked potentials versus locoregional anaesthesia in the monitoring of cerebral function during carotid artery surgery: preliminary results of a prospective study.

E Sbarigia1, A Schioppa, M Misuraca, M A Panico, C Battocchio, C Maraglino, F Speziale, P Fiorani.   

Abstract

OBJECTIVE: to relate changes in somatosensory-evoked potentials (SEPs) with onset of neurological deficits in patients having carotid endarterectomy (CEA) under locoregional anaesthesia.
METHODS: a prospective study of 50 consecutive patients.
RESULTS: SEPs yielded an accuracy of 98%, specificity 100%, and sensitivity 89%. In all concordant cases the onset of a neurological deficit in awake patients corresponded to a 30--40% reduction in amplitude of N20-P25 waveforms. After shunting, the N20-P25 took 2--3 min to return to normal.
CONCLUSIONS: SEPs are associated with a 2% false negative rate. Their threshold for detecting cerebral ischaemia is lower than the currently reported value for patients under general anaesthesia. The time needed for evoked potentials (2--3 min) to return to normal after shunting limits their usefulness in verifying effective shunting. Copyright 2001 Harcourt Publishers Limited.

Entities:  

Mesh:

Year:  2001        PMID: 11352515     DOI: 10.1053/ejvs.2001.1342

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  3 in total

Review 1.  [Anesthesia for carotid artery surgery. Is there a gold standard?].

Authors:  T Rössel; R J Litz; A R Heller; T Koch
Journal:  Anaesthesist       Date:  2008-02       Impact factor: 1.041

Review 2.  [Intraoperative electrophysiological monitoring with evoked potentials].

Authors:  R Nitzschke; N Hansen-Algenstaedt; J Regelsberger; A E Goetz; M S Goepfert
Journal:  Anaesthesist       Date:  2012-04       Impact factor: 1.041

3.  Effects of regional anesthesia techniques on local anesthetic plasma levels and complications in carotid surgery: a randomized controlled pilot trial.

Authors:  Thomas Rössel; Christopher Uhlig; Jörg Pietsch; Stefan Ludwig; Thea Koch; Torsten Richter; Peter Markus Spieth; Stephan Kersting
Journal:  BMC Anesthesiol       Date:  2019-11-26       Impact factor: 2.217

  3 in total