Literature DB >> 11348976

Iatrogenic paradoxical air embolism in pulmonary hypertension.

B W Holcomb1, J E Loyd, B F Byrd, T T Wilsdorf, T Casey-Cato, W R Mason, I M Robbins.   

Abstract

Paradoxical systemic air embolism (PAE) occurring as a complication of right-to-left intracardiac shunting during evaluation and treatment of pulmonary hypertension (PH) has not been previously reported. We report four cases of PH-associated PAE recently encountered at our center. Two patients with PH experienced transient neurologic deficits during agitated-saline contrast echocardiography (ASCE), and a patent foramen ovale was subsequently diagnosed in both patients. Two patients with Eisenmenger's syndrome (ES), while receiving epoprostenol via multilumen catheters, experienced transient neurologic deficits while flushing the unused port of the catheter. No patient experienced permanent neurologic deficits. We conclude that ASCE poses a risk for PAE in patients with PH and clinically silent, previously undetected, right-to-left intracardiac shunts, and that multilumen catheters used for long-term epoprostenol therapy in ES carry a risk of PAE.

Entities:  

Mesh:

Year:  2001        PMID: 11348976     DOI: 10.1378/chest.119.5.1602

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  Air embolism during CT-guided transthoracic needle biopsy.

Authors:  Wolfgang Lederer; Christoph J Schlimp; Bernhard Glodny; Franz J Wiedermann
Journal:  BMJ Case Rep       Date:  2011-06-30

2.  Electrical injury of the neck and cardiac air embolism: a novel mechanism of death.

Authors:  Indira Kitulwatte; Michael S Pollanen
Journal:  Forensic Sci Med Pathol       Date:  2008-09-20       Impact factor: 2.007

3.  Venous and arterial air embolism: a rare phenomenon with fatal consequences.

Authors:  Jatan Shah; Nasheena Jiwa; Natasha Mamdani; David Hill
Journal:  BMJ Case Rep       Date:  2016-12-05

4.  Paradoxical carbon dioxide embolism during endoscopic thyroidectomy confirmed by transesophageal echocardiography.

Authors:  Seong-Hyop Kim; Kyoung-Sik Park; Hwa-Yong Shin; Jun-Hee Yi; Duk-Kyung Kim
Journal:  J Anesth       Date:  2010-08-05       Impact factor: 2.078

5.  Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles.

Authors:  Hanwook Park; Eunseop Yeom; Seung-Jun Seo; Jae-Hong Lim; Sang-Joon Lee
Journal:  Sci Rep       Date:  2015-03-06       Impact factor: 4.379

6.  Acute management of vascular air embolism.

Authors:  Nissar Shaikh; Firdous Ummunisa
Journal:  J Emerg Trauma Shock       Date:  2009-09
  6 in total