Literature DB >> 11348488

Inadequacy of low-volume resuscitation with hemoglobin-based oxygen carrier hemoglobin glutamer-200 (bovine) in canine hypovolemia.

B Driessen1, J S Jahr, F Lurie, R A Gunther.   

Abstract

Stroma-free hemoglobin-based oxygen carriers (HBOC) have been developed to overcome problems associated with transfusion of allogeneic blood. We have studied the efficacy of the first licensed veterinary blood substitute, hemoglobin glutamer-200 bovine (Oxyglobin; Biopure, Cambridge, MA, USA, Hb-200), in a canine model of acute hypovolemia and examined whether clinically commonly used criteria are adequate to guide fluid resuscitation with this product. Twelve anesthetized dogs were instrumented for measurements of physiological variables including hemodynamic, oxygenation, and blood gas and acid-base parameters. Dogs were bled to a mean arterial pressure (MAP) of 50 mmHg for 1 h followed by resuscitation with either shed blood (controls) or Hb-200 until heart rate (HR), MAP and central venous pressure (CVP) returned to baseline. Recordings were repeated immediately and 3 h after termination of fluid resuscitation. Hemorrhage (average 32 mL/kg) caused significant decreases in total hemoglobin (Hb), mean pulmonary arterial pressure (PAP), cardiac output (CO) and oxygen delivery (DO2I), increases in HR and systemic vascular resistance (SVRI), and lactic acidosis. In controls, only re-transfusion of all shed blood returned HR, MAP and CVP to prehemorrhage values, whereas in other dogs this endpoint was reached with infusion of 10 mL/kg Hb-200. Unlike blood transfusion, Hb-200 infusion failed to return CI and DO2I to baseline and to increase arterial oxygen content (CaO2) and total Hb; SVRI further increased. Thus, commonly used criteria (HR, MAP, CVP) to guide transfusion therapy in patients posthemorrhage prove insufficient when HBOCs with pronounced vasoconstrictive action are used and lead to inadequate volume repletion.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11348488     DOI: 10.1046/j.1365-2885.2001.00307.x

Source DB:  PubMed          Journal:  J Vet Pharmacol Ther        ISSN: 0140-7783            Impact factor:   1.786


  5 in total

1.  Simulation of NO and O2 transport facilitated by polymerized hemoglobin solutions in an arteriole that takes into account wall shear stress-induced NO production.

Authors:  Yipin Zhou; Pedro Cabrales; Andre F Palmer
Journal:  Biophys Chem       Date:  2012-01-09       Impact factor: 2.352

2.  Tangential flow filtration facilitated fractionation and PEGylation of low and high-molecular weight polymerized hemoglobins and their biophysical properties.

Authors:  Xiangming Gu; Chintan Savla; Andre F Palmer
Journal:  Biotechnol Bioeng       Date:  2021-10-26       Impact factor: 4.530

3.  Broadband diffuse optical spectroscopy assessment of hemorrhage- and hemoglobin-based blood substitute resuscitation.

Authors:  Jangwoen Lee; Jae G Kim; Sari Mahon; Bruce J Tromberg; David Mukai; Kelly Kreuter; Darin Saltzman; Renee Patino; Robert Goldberg; Matthew Brenner
Journal:  J Biomed Opt       Date:  2009 Jul-Aug       Impact factor: 3.170

4.  Blood substitutes: Basic science, translational studies and clinical trials.

Authors:  Jonathan S Jahr
Journal:  Front Med Technol       Date:  2022-08-18

Review 5.  Colloids Yes or No? - a "Gretchen Question" Answered.

Authors:  Katja-Nicole Adamik; Ivayla D Yozova
Journal:  Front Vet Sci       Date:  2021-07-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.