Literature DB >> 11347829

Osteolysis in a cementless, second generation metal-on-metal hip replacement.

P E Beaulé1, P Campbell, J Mirra, J C Hooper, T P Schmalzried.   

Abstract

A 65-year-old man with osteoarthritis of the hip underwent a cementless total hip replacement with a modern generation, metal-on-metal bearing. Two years later the patient presented with localized osteolysis at the tip of the femoral stem. At the time of revision, the stem was found to be well-fixed. Extensive analyses of the bearing surfaces and periprosthetic tissues were done. There was minimal bearing surface wear and only small numbers of inflammatory cells, such as macrophages, in the tissues, and it was concluded that this was not a typical case of particle-induced osteolysis. All cultures and laboratory studies were negative for infection. This case report supports the multifactorial nature of osteolysis, which includes the osteolytic potential of joint fluid access to and fluid pressures within, the effective joint space.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11347829     DOI: 10.1097/00003086-200105000-00020

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

Review 1.  The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

Authors:  William T Long
Journal:  Iowa Orthop J       Date:  2005

2.  Survivorship of the Charnley Elite Plus cemented femoral stem.

Authors:  M Rowsell; J Der Tavitian; S Birtwistle; R Power
Journal:  Int Orthop       Date:  2005-06-14       Impact factor: 3.075

Review 3.  The lexicon for periprosthetic bone loss versus osteolysis after cervical disc arthroplasty: a systematic review.

Authors:  Jenna M Wahbeh; Sang-Hyun Park; Patricia Campbell; Edward Ebramzadeh; Sophia N Sangiorgio
Journal:  Eur Spine J       Date:  2022-01-09       Impact factor: 3.134

4.  Intraosseous lymphocytic infiltrates after hip resurfacing arthroplasty : a histopathological study on 181 retrieved femoral remnants.

Authors:  Jozef Zustin; Michael Amling; Matthias Krause; Stefan Breer; Michael Hahn; Michael M Morlock; Wolfgang Rüther; Guido Sauter
Journal:  Virchows Arch       Date:  2009-02-19       Impact factor: 4.064

5.  Comparison of metal on metal versus polyethylene-ceramic bearing in uncemented total hip arthroplasty in patients with haemophilic arthropathy.

Authors:  Joannis Panotopoulos; Cihan Ay; Reinhard Schuh; Stephan Domayer; Philipp Funovics; Klemens Trieb; Hugo Wanivenhaus; Reinhard Windhager
Journal:  Int Orthop       Date:  2014-04-12       Impact factor: 3.075

Review 6.  [Particle release in metal-on-metal bearings. A risk analysis].

Authors:  C Heisel; M Thomsen; E Jakubowitz; J P Kretzer
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

Review 7.  Mechanically Induced Periprosthetic Osteolysis: A Systematic Review.

Authors:  Benjamin A McArthur; Ryan Scully; F Patrick Ross; Mathias P G Bostrom; Anna Falghren
Journal:  HSS J       Date:  2018-11-09

8.  The Epidemiology and National Trends of Bearing Surface Usage in Primary Total Hip Arthroplasty in Korea.

Authors:  Pil Whan Yoon; Jeong Joon Yoo; Yunjung Kim; Seungmi Yoo; Sahnghoon Lee; Hee Joong Kim
Journal:  Clin Orthop Surg       Date:  2016-02-13

Review 9.  Immunological Responses to Total Hip Arthroplasty.

Authors:  Kenny Man; Lin-Hua Jiang; Richard Foster; Xuebin B Yang
Journal:  J Funct Biomater       Date:  2017-08-01
  9 in total