Literature DB >> 11346701

Performance characteristics of the COBAS AmpliScreen HIV-1 test, version 1.5, an assay designed for screening plasma mini-pools.

Y Yang1, M H Lamendola, M Mendoza, D Xu, M Nguyen, S Yeh, Y Wu, J Ku, M Rosenstraus, R Sun.   

Abstract

BACKGROUND: The COBAS AmpliScreen HIV-1 test, version 1.5 (v1.5) (Roche Molecular Systems), is designed for screening pools composed of samples from 24 individual units of blood or plasma. A specimen-processing procedure (Multiprep) simultaneously concentrates and extracts HIV-1, HCV, and HBV particles from plasma and incorporates an HIV-1 internal control (IC) RNA. Processed samples are amplified by RT-PCR using HIV-1-specific primers and detected by hybridization of the amplified products to HIV-1- and IC-specific oligonucleotide probes. STUDY DESIGN AND METHODS: Plasma samples containing known quantities of HIV-1 were used to evaluate analytical sensitivity and precision and to validate a pool testing algorithm. Analytical specificity was evaluated by adding various viruses and bacteria to HIV-1-negative plasma. Seroconversion panels were tested to estimate the window-period reduction achieved by RNA testing.
RESULTS: The analytical sensitivity of the test (concentration that yields > or = 95% positive results in a set of replicate tests) was 25 copies of HIV-1 RNA per mL of pooled plasma. Representative strains from all HIV-1 group M subtypes were reproducibly detected (> 95% positive results) at concentrations of 20 to 200 viral particles per mL. The test did not cross-react with a set of 31 viral and 5 bacterial isolates, and it yielded negative results on a panel of 500 blood samples from HIV-1-seronegative donors. Plasma samples containing abnormally high levels of Hb, albumin, triglycerides, or bilirubin did not interfere with the test. HIV-1 RNA was detected 2 to 14 days before HIV-1 antibody and 0 to 28 days before p24 antigen. The test specifically detected pools containing a single positive unit with 2400 HIV-1 RNA copies per mL and correctly identified the positive unit.
CONCLUSION: The COBAS AmpliScreen HIV-1 test, v1.5, has sufficient sensitivity to detect a single infected unit containing 600 copies of HIV-1 per mL in a pool with 23 uninfected units and should reduce the window period between infection and seroconversion by at least 2 to 14 days.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11346701     DOI: 10.1046/j.1537-2995.2001.41050643.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  Evaluation of the clinical sensitivities of three viral load assays with plasma samples from a pediatric population predominantly infected with human immunodeficiency virus type 1 subtype G and BG recombinant forms.

Authors:  Rute Antunes; Sofia Figueiredo; Inês Bártolo; Manuel Pinheiro; Lino Rosado; Isabel Soares; Helena Lourenço; Nuno Taveira
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

2.  Rapid detection and quantification of RNA of Ebola and Marburg viruses, Lassa virus, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus, dengue virus, and yellow fever virus by real-time reverse transcription-PCR.

Authors:  Christian Drosten; Stephan Göttig; Stefan Schilling; Marcel Asper; Marcus Panning; Herbert Schmitz; Stephan Günther
Journal:  J Clin Microbiol       Date:  2002-07       Impact factor: 5.948

  2 in total