Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla?

C Vahlhaus1, T Sommer, T Lewalter, R Schimpf, B Schumacher, W Jung, B Lüderitz.   

Abstract

The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 +/- 29.6 minutes (mean +/- SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.

Entities:  

Mesh:

Year:  2001        PMID: 11341087     DOI: 10.1046/j.1460-9592.2001.00489.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  21 in total

1.  Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T.

Authors:  Ariel Roguin; Menekhem M Zviman; Glenn R Meininger; E Rene Rodrigues; Timm M Dickfeld; David A Bluemke; Albert Lardo; Ronald D Berger; Hugh Calkins; Henry R Halperin
Journal:  Circulation       Date:  2004-07-26       Impact factor: 29.690

2.  Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study.

Authors:  Mrinal Yadava; Matthew Nugent; Angela Krebsbach; Jessica Minnier; Peter Jessel; Charles A Henrikson
Journal:  J Interv Card Electrophysiol       Date:  2017-07-22       Impact factor: 1.900

Review 3.  Safety of implanted cardiac devices in an MRI environment.

Authors:  Esra Gucuk Ipek; Saman Nazarian
Journal:  Curr Cardiol Rep       Date:  2015-07       Impact factor: 2.931

Review 4.  Viewpoint: Cardiac implantable electronic devices and magnetic resonance compatibility: was it really necessary?

Authors:  Richard Sutton; David G Benditt
Journal:  J Interv Card Electrophysiol       Date:  2019-02-22       Impact factor: 1.900

5.  Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.

Authors:  Saman Nazarian; Rozann Hansford; Amir A Rahsepar; Valeria Weltin; Diana McVeigh; Esra Gucuk Ipek; Alan Kwan; Ronald D Berger; Hugh Calkins; Albert C Lardo; Michael A Kraut; Ihab R Kamel; Stefan L Zimmerman; Henry R Halperin
Journal:  N Engl J Med       Date:  2017-12-28       Impact factor: 91.245

6.  A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices.

Authors:  Saman Nazarian; Rozann Hansford; Ariel Roguin; Dorith Goldsher; Menekhem M Zviman; Albert C Lardo; Brian S Caffo; Kevin D Frick; Michael A Kraut; Ihab R Kamel; Hugh Calkins; Ronald D Berger; David A Bluemke; Henry R Halperin
Journal:  Ann Intern Med       Date:  2011-10-04       Impact factor: 25.391

7.  Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla.

Authors:  Saman Nazarian; Ariel Roguin; Menekhem M Zviman; Albert C Lardo; Timm L Dickfeld; Hugh Calkins; Robert G Weiss; Ronald D Berger; David A Bluemke; Henry R Halperin
Journal:  Circulation       Date:  2006-09-11       Impact factor: 29.690

Review 8.  MRI for patients with cardiac implantable electrical devices.

Authors:  Grant V Chow; Saman Nazarian
Journal:  Cardiol Clin       Date:  2014-02-12       Impact factor: 2.213

Review 9.  MRI in patients with cardiac devices.

Authors:  Edward T Martin; David A Sandler
Journal:  Curr Cardiol Rep       Date:  2007-03       Impact factor: 2.931

10.  Magnetic resonance imaging conditional pacemakers: rationale, development and future directions.

Authors:  Edmond M Cronin; Bruce L Wilkoff
Journal:  Indian Pacing Electrophysiol J       Date:  2012-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.