Literature DB >> 11340555

Accuracy of radiography, nuclear scintigraphy, and histopathology for determining the proximal extent of distal radius osteosarcoma in dogs.

N F Leibman1, C A Kuntz, P F Steyn, M J Fettman, B E Powers, S J Withrow, W S Dernell.   

Abstract

OBJECTIVE: To compare the accuracy of radiography, nuclear scintigraphy, and histopathology for determining the proximal extent of distal radius osteosarcoma in dogs. STUDY
DESIGN: Retrospective clinical study. SAMPLE POPULATION: Twenty client-owned dogs taken to Colorado State University with osteosarcoma of the distal radius.
METHODS: Medical records of 20 dogs with confirmed osteosarcoma that underwent a limb-salvage procedure were reviewed. Measurements were performed directly from the lateral view of each radius, from both the scintigram and the radiograph, to determine the length of the radius and the distance from the proximal extent of the tumor to the distal radiographic or scintographic extent of the radius. The ratio of distal radial involvement to total radius length was calculated. A similar ratio was also determined using the macroslide, which included the entire portion of bone that was excised during the limb-salvage procedure. All 3 methods of measurement were compared.
RESULTS: Nuclear scintigraphy significantly overestimated tumor length when compared with macroslide specimen measurements. Radiography also overestimated tumor length, but these results were not significantly different from macroslide specimen measurements.
CONCLUSIONS: Both radiography and nuclear scintigraphy overestimate the extent of distal radius osteosarcoma in dogs when compared with histopathologic macroslides of the same lesions. Nuclear scintigraphy overestimated tumor extent to a larger degree than did radiography. CLINICAL RELEVANCE: Although radiography is a more accurate method of measurement of the extent of distal radius osteosarcoma, because nuclear scintigraphy overestimates tumor length to a greater degree, scintigraphy may provide a larger margin of safety for determining the site of proximal osteotomy during a limb-salvage procedure. However, caution should be taken when utilizing scintigraphy, because this method may overestimate length of radius involved to such an extent as to cause the surgeon to believe that a patient is not a suitable limb-salvage candidate. Copyright 2001 by The American College of Veterinary Surgeons

Entities:  

Mesh:

Year:  2001        PMID: 11340555     DOI: 10.1053/jvet.2001.23351

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  3 in total

1.  Free proximal cortical ulnar autograft for the treatment of distal radial osteosarcoma in a dog.

Authors:  Esteban Gonzalez Gasch; Pablo Rivier; Jean François Bardet
Journal:  Can Vet J       Date:  2013-02       Impact factor: 1.008

2.  Accuracy of computed tomography in determining lesion size in canine appendicular osteosarcoma.

Authors:  Ketaki S Karnik; Valerie F Samii; Steven E Weisbrode; Cheryl A London; Eric M Green
Journal:  Vet Radiol Ultrasound       Date:  2012-03-14       Impact factor: 1.363

Review 3.  Imaging in Non-neurologic Oncologic Treatment Planning of the Head and Neck.

Authors:  Katherine S Hansen; Michael S Kent
Journal:  Front Vet Sci       Date:  2019-03-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.