Literature DB >> 11339584

Scleral contact lenses for overnight wear in the management of ocular surface disorders.

M J Tappin1, K W Pullum, R J Buckley.   

Abstract

PURPOSE: To describe the use of overnight wear scleral contact lenses (Scl CLs). The authors describe 7 patients using this modality of contact lens wear. Most of the lenses were made from highly gas-permeable materials, but a long-standing case is also reported when the lenses were made from PMMA, which is impermeable to gases.
BACKGROUND: There is a range of therapeutic indications for the use of Scl CLs. The development of rigid gas-permeable (RGP) materials has widened this range. CASE REPORTS: Seven case reports are presented which describe patients in whom severe ocular surface disease has been managed with overnight-wear Scl CLs. The indications were: corneal exposure, post-radiotherapy complications, Stevens Johnson disease, recurrent erosion and congenital or post-surgical lid defects.
CONCLUSION: Scl CLs provide a therapeutic option for a range of complicated corneal and ocular surface conditions for which the treatment by other methods is either unsuitable or less effective. They have several advantages over silicone rubber and hydrogel lenses. The relative ease of handling for some patients allows removal for cleaning, their rigidity gives stability and a high degree of protection to the ocular surface, and the presence of a pre-corneal fluid reservoir optically neutralises an irregular corneal surface. Highly oxygen-permeable materials enable consideration of overnight wear in appropriate circumstances.

Entities:  

Mesh:

Year:  2001        PMID: 11339584     DOI: 10.1038/eye.2001.54

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  6 in total

1.  The natural history of Stevens Johnson syndrome: patterns of chronic ocular disease and the role of systemic immunosuppressive therapy.

Authors:  M Victoria De Rojas; John K G Dart; Valerie P J Saw
Journal:  Br J Ophthalmol       Date:  2007-02-21       Impact factor: 4.638

2.  [Gas permeable scleral lenses as a conservative treatment option for extreme corneal ectasias and severe dry eye].

Authors:  K T Hänisch; B Neppert; G Geerling
Journal:  Ophthalmologe       Date:  2005-04       Impact factor: 1.059

3.  Therapeutic use of mini-scleral lenses in a patient with Graves' ophthalmopathy.

Authors:  Jennifer S Harthan
Journal:  J Optom       Date:  2013-01-09

Review 4.  Contact Lens-related Complications: A Review.

Authors:  Fateme Alipour; Saeed Khaheshi; Mahya Soleimanzadeh; Somayeh Heidarzadeh; Sepideh Heydarzadeh
Journal:  J Ophthalmic Vis Res       Date:  2017 Apr-Jun

Review 5.  Therapeutic uses of scleral contact lenses for ocular surface disease: patient selection and special considerations.

Authors:  Jennifer S Harthan; Ellen Shorter
Journal:  Clin Optom (Auckl)       Date:  2018-07-11

6.  Role of mini-scleral lens in mucous membrane pemphigoid.

Authors:  Mukesh Kumar; Rohit Shetty; Chaitra Jayadev
Journal:  Indian J Ophthalmol       Date:  2017-04       Impact factor: 1.848

  6 in total