Literature DB >> 11339184

The role of ductus venosus blood flow assessment in screening for chromosomal abnormalities at 10-16 weeks of gestation.

E Antolín1, C Comas, M Torrents, A Muñoz, F Figueras, M Echevarría, M Cararach, J M Carrera.   

Abstract

OBJECTIVE: To evaluate the role of ductus venosus blood flow assessment at 10-16 weeks' gestation in screening for chromosomal abnormalities.
METHODS: Ductus venosus blood flow was prospectively evaluated in 1371 consecutive pregnancies between 10 and 16 weeks of gestation. The pulsatility index for veins was calculated. All cases were screened for chromosomal defects combining maternal age and fetal nuchal translucency thickness.
RESULTS: A chromosomal abnormality was found in 20 cases. The overall detection rate, specificity, positive predictive value, negative predictive value and odds ratio for chromosomal abnormalities were 65%, 95.7%, 18.3%, 99.5% and 41 (95% CI 16-108), respectively, when using the 95th centile pulsatility index as a cut-off.
CONCLUSIONS: These preliminary results suggest that evaluation of the ductus venosus pulsatility index at 10-16 weeks' gestation is a useful second-line screening test for chromosomal defects. A combination of nuchal translucency measurement and ductus venosus assessment might increase specificity while maintaining an optimal detection rate for chromosomal abnormalities. Such a policy could identify 55% of all chromosomal abnormalities and about 69% of autosomal trisomies, reducing the need for invasive testing to less than 1%.

Entities:  

Mesh:

Year:  2001        PMID: 11339184     DOI: 10.1046/j.1469-0705.2001.00395.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

Review 1.  Indications for fetal echocardiography.

Authors:  M Small; J A Copel
Journal:  Pediatr Cardiol       Date:  2004 May-Jun       Impact factor: 1.655

2.  Human fetal cardiac function during the first trimester of pregnancy.

Authors:  K Mäkikallio; P Jouppila; J Räsänen
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

3.  The assessment of nuchal translucency and serum markers for down syndrome screening with ductus venosus Doppler measurements in the first trimester.

Authors:  Ozlem Ozer; Cenk N Sayın; Füsun G Varol
Journal:  J Turk Ger Gynecol Assoc       Date:  2010-12-01

4.  Employ ductus venous blood flow in the early detection of trisomy 21, trisomy 18, and trisomy 13: A meta-analysis.

Authors:  Yibing Ge; Lili Xia; Yun Wu; Hongbao Cao
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.