Literature DB >> 11337243

Failure strengths of suture vs. biodegradable arrow and staple for meniscal repair: an in vitro study.

S P Walsh1, S L Evans, D M O'Doherty, I W Barlow.   

Abstract

A study was performed to determine the in vitro biomechanical behaviour of two 'all inside' meniscal repair techniques (Meniscal Arrow [Bionx Implants Inc.] and Meniscal Staple [Surgical Dynamics Inc.]) and compare these directly with both a horizontal and vertical suture repair. Using 30 fresh bovine medial menisci, vertical 'bucket handle' tears were created 4 mm from the meniscus periphery. Repairs were subsequently performed, using four techniques, with 15 repairs in each group, a horizontally placed 3-metric Ethibond suture, a vertically placed 3-metric Ethibond suture, a single 13-mm arrow and a single 7-mm staple. A tensile test was performed to determine the force at failure for each technique. The mean force at failure of the horizontal and vertical suture groups was 63.2 and 73.9 N, respectively, 44.3 N for the arrow group and 17.8 N for the staple group. The mean forces at failure were significantly different (P < 0.005). The mean tensile strength of the meniscal staple was significantly lower than that of both suture and arrow groups. The 7-mm staple design may not allow adequate interdigitation between the barbed legs and the semicircular collagen fibres of the meniscus.

Entities:  

Mesh:

Year:  2001        PMID: 11337243     DOI: 10.1016/s0968-0160(00)00084-3

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  5 in total

1.  A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

Authors:  Thore Zantop; Anne Kathleen Eggers; Volker Musahl; Andre Weimann; Joachim Hassenpflug; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-12-19       Impact factor: 4.342

2.  Mechanical comparison of meniscal repair devices with mattress suture devices in vitro.

Authors:  Brian C Aros; Angela Pedroza; William K Vasileff; Alan S Litsky; David C Flanigan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-09       Impact factor: 4.342

Review 3.  Meniscus tear surgery and meniscus replacement.

Authors:  Javier Vaquero; Francisco Forriol
Journal:  Muscles Ligaments Tendons J       Date:  2016-05-19

4.  Meniscal repair in anterior cruciate ligament reconstruction: a long-term outcome study.

Authors:  J T K Melton; J R Murray; A Karim; H Pandit; F Wandless; N P Thomas
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-09       Impact factor: 4.342

5.  Complications in medial meniscus suture: a cadaveric study.

Authors:  Alejandro Espejo-Baena; Pau Golano; Stephan Meschian; Jose Maria Garcia-Herrera; J M Serrano Jiménez
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-06-07       Impact factor: 4.114

  5 in total