[Distal radius fractures--retrospective quality control after conservative and operative therapy].

C Sommer1, L Brendebach, R Meier, A Leutenegger.   

Abstract

BACKGROUND: The distal radius fracture is the most frequent fracture in the adult patient. The wide spectrum of different types of fracture and the coexisting factors make the choice for the optimal treatment difficult. As an interne quality control we retrospectively evaluated all patients with distal radius fractures treated in 1995 at our institution.
METHODS: The study included 69 adult patients with 71 distal radius fractures. After on average 26 months 58 patients with 59 fractures were clinically and radiologically evaluated. The patients were asked to give supplementary information about their follow-up treatment as well as any remaining physical difficulties and limitations in the daily life. All x-rays of the broken radius were carefully analysed and compared with the opposite side. The final results were evaluated according to the "Demerit Point System".
RESULTS: Patients were treated with five different therapeutical methods. 76.3% of the patients showed a very good/good final result. In 56.7% of the cases secondary fracture dislocation occurred; the dislocation-rate of fractures treated with percutaneous k-wires was 93.3%! A clear correlation between secondary displacement and final results was found.
CONCLUSION: A main factor for an optimal outcome is the anatomic restoration of length and axis of the distal radius as well as of joint congruency, also moderate angular deformities are well tolerated. Our collective showed an unexpected high rate of secondary displacement, especially in the k-wire group. The reasons for this unsatisfactory event are manifold: too optimistic indication, insufficient follow-up examination in the first four to six weeks, inconsequent change to a more stable fixation method in case of a secondary dislocation. The results of this retrospective evaluation had a major impact on our concept of treatment. The dorso-radial double-plate technique combined with bone graft will be more used in the future especially in younger patients. The new standardised concept is the base of a present prospective study.

Entities:  

Mesh:

Year:  2001        PMID: 11332267     DOI: 10.1024/1023-9332.7.2.68

Source DB:  PubMed          Journal:  Swiss Surg        ISSN: 1023-9332


  3 in total

1.  A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating.

Authors:  Yih-Shiunn Lee; Tien-Yung Wei; Yu-Chieh Cheng; Tzu-Liang Hsu; Chien-Rae Huang
Journal:  Int Orthop       Date:  2011-12-13       Impact factor: 3.075

Review 2.  [Osteoporotic fractures of the distal radius. What is new?].

Authors:  J Meiners; C Jürgens; S Mägerlein; S Wallstabe; B Kienast; M Faschingbauer
Journal:  Chirurg       Date:  2012-10       Impact factor: 0.955

3.  Type C distal radial fractures treated with conventional AO plates: an easy and cost-saving solution in a locking plate era.

Authors:  Bas Twigt; Michael Bemelman; Koen Lansink; Loek Leenen
Journal:  Int Orthop       Date:  2013-01-11       Impact factor: 3.075