AIM: The purpose of the study was the characterization of a type of rupture occurring on warp-knitted polyester vascular prostheses.
MATERIALS AND METHODS: We studied 20 cases of warp-knitted polyester vascular prostheses that were explanted from humans that showed a longitudinal rupture as a part of a collaborative retrieval program. All the prostheses were immediately fixed in a 10% formaldehyde solution after their explantation in the operating room. The clinical data of these cases were recorded. The explants were photographed, washed to eliminate the surrounding tissues, and photographed again. The ruptures were characterized with macroscopic examination, optical stereomicroscopy, and scanning electron microscopy.
RESULTS: The mean duration of implantation of the prostheses was 16.0 +/- 3.3 years (range, 9-20.7 years). The prostheses were Cooley Double Velour (n = 15) and Microvel Double Velour (n = 5). There were 16 aortobifemoral bypass grafts, 1 aorto-biiliac, 1 aorto-aortic, 1 iliofemoral, and 1 axillobifemoral. The longitudinal ruptures occurred on two specific parts of the prostheses: the guide line (6 cases) and the remeshing line (11 cases). In three cases both lines were affected. Scanning electron microscopy showed major degradation of the trilobar filaments of the velour and gradual ruptures of the flat filaments of the remeshing and guide lines.
CONCLUSIONS: In this study, we have identified a specific mechanism of late (9-20 years) longitudinal rupture of knitted polyester prostheses consisting of degradation of the polyester filaments along the remeshing and guide lines that run the length of the graft.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11331843     DOI: 10.1067/mva.2001.113493

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

1.  Treatment of Dacron Grafting Dilatation with Endovascular Stent Graftıng.

Authors:  Murat Ugurlucan; Didem Melis Oztas; Yilmaz Onal; Cagla Canbay; Omer Ali Sayin; Mehmet Barburoglu; Muslum Ercument Filik; Deniz Ocal; Mehmet Buget; Bulent Acunas; Ufuk Alpagut
Journal:  Aorta (Stamford)       Date:  2016-10-01

Review 2.  Bioprinting of freestanding vascular grafts and the regulatory considerations for additively manufactured vascular prostheses.

Authors:  Sara Abdollahi; Joseph Boktor; Narutoshi Hibino
Journal:  Transl Res       Date:  2019-06-03       Impact factor: 7.012

3.  Pseudoaneurysm in the Left Groin due to Ruptured Knitted Dacron Graft.

Authors:  Masahiro Ryugo; Takumi Yasugi; Mitsugi Nagashima; Hironori Izutani; Toru Okamura; Fumiaki Shikata; Masashi Kawamura; Kanji Kawachi
Journal:  Ann Vasc Dis       Date:  2011-06-02

4.  Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts.

Authors:  Satoshi Yamamoto; Katsuyuki Hoshina; Hideo Kimura; Hiroyuki Okamoto; Kunihiro Shigematsu; Tetsuro Miyata; Toshiaki Watanabe
Journal:  Surg Today       Date:  2014-04-03       Impact factor: 2.549

Review 5.  Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries.

Authors:  Charanpreet Singh; Cynthia S Wong; Xungai Wang
Journal:  J Funct Biomater       Date:  2015-06-30

6.  Late Disruption of a Polyethylene Terephthalate Aortic Graft 30 Years after Initial Graft Placement.

Authors:  Akihito Matsushita; Yu Tsunoda; Takashi Hattori; Wahei Mihara
Journal:  EJVES Short Rep       Date:  2017-12-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.