BACKGROUND: An infection control problem in dental operatories which is not fully controlled is waterline contamination by heterotrophic mesophilic bacteria. These bacteria are present in water supplies as a planktonic phase and adhere to the lumen of tubings as a biofilm comprised of their external cell surface glycocalyx and by production of extracellular carbohydrate polymers. The adherent film is most difficult to remove. The accumulated planktonic phase can be reduced significantly by flushing water from the lines before use in patient treatment, but will return when the equipment is idle through the accumulation of more planktonic phase and by slough of the biofilm surface-adsorbed phase not yet enmeshed in the carbohydrate matrix. Chlorine dioxide has antimicrobial activity against many bacteria, spores, and viruses. It is used in water supply treatment as a disinfectant and slime preventive and has an advantage over chlorine in that carcinogenic trihalomethanes are not generated.
METHODS: This study compared use of phosphate buffer-stabilized chlorine dioxide (0.1%) mouthrinse as a lavage in ultrasonic dental scaler units with the use of tap water as a control. Sterile water flushed through the units onto heterotrophic plate count (HPC) sampler plates was cultured 7 days at room temperature and colonies were counted at 12x. One test and one control unit were used for biopsy of internal tubing and scanning electron microscopy imaging.
RESULTS: The HPC counts, in colony forming units (CFU)/ml, were reduced 3- to 5-fold by flushing tap water through the units, but they returned after units were idle overnight. When phosphate-buffered chlorine dioxide mouthrinse was used as a lavage, CFU/ml were reduced 12- to 20-fold. Holding chlorine dioxide in waterlines overnight reduced recurrent buildup compared to water (P <0.05). Scanning electron microscopy images indicated a significant reduction of biofilm coverage by chlorine dioxide as compared to water (P<0.001).
CONCLUSIONS: Phosphate-buffered chlorine dioxide mouthrinse was effective in these short-term trials for control of waterline contamination in ultrasonic dental scaling units. It should prove as useful in dental professional waterline applications as it has in industrial uses for biofilm control.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11327069     DOI: 10.1902/jop.2001.72.3.401

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  4 in total

1.  Microbiological evaluation of a range of disinfectant products to control mixed-species biofilm contamination in a laboratory model of a dental unit water system.

Authors:  J T Walker; D J Bradshaw; M R Fulford; P D Marsh
Journal:  Appl Environ Microbiol       Date:  2003-06       Impact factor: 4.792

2.  A new chemical formulation for control of dental unit water line contamination: An 'in vitro' and clinical 'study'

Authors:  Lucio Montebugnoli; Giovanni Dolci
Journal:  BMC Oral Health       Date:  2002       Impact factor: 2.757

Review 3.  Antiviral mouthwashes: possible benefit for COVID-19 with evidence-based approach.

Authors:  Mahdieh-Sadat Moosavi; Pouyan Aminishakib; Maryam Ansari
Journal:  J Oral Microbiol       Date:  2020-07-17       Impact factor: 5.474

4.  The efficacy of disinfectants in the decontamination of dental unit water lines: an in vitro laboratory study.

Authors:  Mrudula Patel; Jainisha Desai; Peter C Owen
Journal:  BDJ Open       Date:  2016-02-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.