The value of the LA48 linear ion chamber array for characterization of intensity-modulated beams.

C Martens1, C De Wagter, W De Neve.   

Abstract

In this paper the performance of the LA48 linear ion chamber array (PTW, Freiburg, Germany) for characterization of intensity-modulated (IM) beams was investigated. First, some elementary properties were explored. A series of beam penumbras and output factors for small rectangular fields were measured at 6 and 18 MV, and the results were compared with data obtained using a diamond detector. The energy and dose rate dependence of the array response were examined, and the leakage current was assessed. In a second step, profiles were measured for two clinically delivered IM beams and for a dynamic wedge. The interplay between the sharpening of the penumbra by the upper metal electrode plate of the array and the volume averaging of the 4 x 4 mm ion chamber elements results in precise measurements, even in regions of high dose gradient. It is true, however, that the metal electrodes imply a small energy spectrum dependence in the array response. The dose rate dependence is found to be negligible. All of this makes, the LA48 linear array a suitable device for analysing dose distributions of clinical IM beams.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11324956     DOI: 10.1088/0031-9155/46/4/316

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification.

Authors:  Sathiyan Saminathan; Ravikumar Manickam; Varatharaj Chandraraj; Sanjay S Supe
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

2.  Clinical Evaluation of a Two-dimensional Liquid-Filled Ion chamber Detector Array for Verification of High Modulation Small Fields in Radiotherapy.

Authors:  Miljenko Markovic; Ganesh Narayanasamy; Sotirios Stathakis; Panayiotis Mavroidis; Ines-Ana Jurkovic; Daniel Saenz; Niko Papanikolaou
Journal:  J Med Phys       Date:  2019 Apr-Jun

3.  Comparison of measured and computed portal dose for IMRT treatment.

Authors:  Savino Cilla; Pietro Viola; Luigi Azario; Luca Grimaldi; Maurizio Craus; Guido D'Onofrio; Andrea Fidanzio; Alessio Giuseppe Morganti; Angelo Piermattei
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102