Literature DB >> 11324209

Early experience with Wide-Platform Mk II implants. Part I: Implant survival. Part II: Evaluation of risk factors involving implant survival.

S E Eckert1, S J Meraw, A L Weaver, C M Lohse.   

Abstract

Part I of this study describes the survival of a wide-platform, wide-diameter implant (Wide-Platform Mk II). Beginning in January 1997, 85 Wide-Platform Mk II implants were placed in the jaws of 63 patients (35 males and 28 females). Male patients experienced 10 implant failures, and female patients lost 9 implants. The mean time of implant follow-up was 286 days (median, 280), with a maximum of 734 days and a minimum of 0 days. Implant loss was 19% in the mandible and 29% in the maxilla. Kaplan-Meier analysis showed a probability of implant failure after 1 year of 0.649 (confidence interval, 0.455 to 0.926) in the maxilla and of 0.751 (confidence interval, 0.616 to 0.915) in the mandible. No apparent relationship was noted between implant survival and implant length. Part II of this study evaluated the association between the survival of a new implant design and a number of potential risk factors. A retrospective chart review was conducted for all patients who received Wide-Platform Mk II implants and who agreed to allow a medical records review for research purposes. Kaplan-Meier survival curves were used to assess the probability of implant survival relative to time. The relationships between implant survival and implant location, history of tobacco use, current tobacco use, sinus grafting, bruxism, and root canal therapy were assessed by Cox proportional hazards modeling. Although the hazard ratio showed an increased risk of implant failure with some factors, particularly a history of root canal therapy in the site of implant placement (hazard ratio 3.2, P = .10), none of the factors were statistically significant. The Wide-Platform Mk II implant used in this population group was associated with a high failure rate, but the failure rate was not related to any specific risk factors reviewed.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11324209

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

1.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

Review 2.  [Sinus floor elevation and augmentation. Evidence-based analysis of prognosis and risk factors].

Authors:  F P Strietzel
Journal:  Mund Kiefer Gesichtschir       Date:  2004-02-06

3.  Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year.

Authors:  Renzo Guarnieri; Dario Di Nardo; Gianni Di Giorgio; Gabriele Miccoli; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2020-04-01

4.  A 5-year retrospective clinical study of the Dentium implants.

Authors:  Jeong-Yol Lee; Hyo-Jin Park; Jong-Eun Kim; Yong-Geun Choi; Young-Soo Kim; Jung-Bo Huh; Sang-Wan Shin
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

5.  Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar: A Three-Dimensional FEA.

Authors:  Shrikar R Desai; I Karthikeyan; Rika Singh
Journal:  ISRN Dent       Date:  2012-03-07

6.  Surgical protocol and short-term clinical outcome of immediate placement in molar extraction sockets using a wide body implant.

Authors:  Stefan Vandeweghe; André Hattingh; Ann Wennerberg; Hugo De Bruyn
Journal:  J Oral Maxillofac Res       Date:  2011-10-01

7.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11

8.  Consecutive Case Series of Healed Single-Molar Sites Immediately Restored with Wide-Diameter Implants: A 1-Year Evaluation.

Authors:  Hadi Antoun; Pierre Cherfane; Bouchra Sojod
Journal:  Int J Dent       Date:  2016-04-18

9.  Retrospective clinical study of ultrawide implants more than 6 mm in diameter.

Authors:  Jeong-Kui Ku; Yang-Jin Yi; Pil-Young Yun; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-08-05

10.  One-stage laser-microtextured implants immediately placed in the inter-radicular septum of molar fresh extraction sockets associated with GBR technique. A case series study.

Authors:  Renzo Guarnieri; Dario Di Nardo; Gianfranco Gaimari; Gabriele Miccoli; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2018-10-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.