Literature DB >> 11323490

Fetus and uteroplacental unit: fast MR imaging with three-dimensional reconstruction and volumetry--feasibility study.

R A Kubik-Huch1, S Wildermuth, L Cettuzzi, A Rake, B Seifert, R Chaoui, B Marincek.   

Abstract

In 22 fetuses, three-dimensional reconstruction was performed on the basis of T2-weighted magnetic resonance (MR) data sets by using a surface-rendering technique. Fetuses and uteroplacental units were segmented manually; volumes were calculated automatically. Three-dimensional reconstruction and volumetry of the fetus and uteroplacental unit are feasible with MR data sets. MR estimates correlated closely with ultrasonographic fetal biometric estimates and birth weight.

Mesh:

Year:  2001        PMID: 11323490     DOI: 10.1148/radiology.219.2.r01ma24567

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Screening of fetal CNS anomalies by MR imaging.

Authors:  Wan-Yuo Guo; Tai-Tong Wong
Journal:  Childs Nerv Syst       Date:  2003-06-18       Impact factor: 1.475

2.  MR assessment of fetal lung development using lung volumes and signal intensities.

Authors:  Thomas M Keller; Annett Rake; Sven C A Michel; Burkhardt Seifert; Josef Wisser; Borut Marincek; Rahel A Kubik-Huch
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

3.  Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation.

Authors:  N J Hilliard; R Hawkes; A J Patterson; M J Graves; A N Priest; S Hunter; C Lees; P A Set; D J Lomas
Journal:  Eur Radiol       Date:  2016-01-20       Impact factor: 5.315

4.  Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts.

Authors:  H Bonel; K A Frei; L Raio; M Meyer-Wittkopf; L Remonda; R Wiest
Journal:  Eur Radiol       Date:  2007-12-13       Impact factor: 5.315

Review 5.  Biomechanics of the fetal membrane prior to mechanical failure: review and implications.

Authors:  Erinn M Joyce; John J Moore; Michael S Sacks
Journal:  Eur J Obstet Gynecol Reprod Biol       Date:  2009-03-19       Impact factor: 2.435

6.  Protocol for the prospective observational clinical study: estimation of fetal weight by MRI to PREdict neonatal MACROsomia (PREMACRO study) and small-for-gestational age neonates.

Authors:  Caroline Kadji; Mieke M Cannie; Andrew Carlin; Jacques C Jani
Journal:  BMJ Open       Date:  2019-03-27       Impact factor: 2.692

7.  Measuring intrauterine growth in healthy pregnancies using quantitative magnetic resonance imaging.

Authors:  Ariunzaya Amgalan; Kushal Kapse; Dhineshvikram Krishnamurthy; Nicole R Andersen; Rima Izem; Ahmet Baschat; Jessica Quistorff; Alexis C Gimovsky; Homa K Ahmadzia; Catherine Limperopoulos; Nickie N Andescavage
Journal:  J Perinatol       Date:  2022-02-23       Impact factor: 3.225

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.