A high-capacity LC/MS system for the bioanalysis of samples generated from plate-based metabolic screening.

J S Janiszewski1, K J Rogers, K M Whalen, M J Cole, T E Liston, E Duchoslav, H G Fouda.   

Abstract

HPLC/MS is a linear technique characterized by serial injection and analysis of individual samples. Parallel-format high-throughput screens for druglike properties present a significant analytical challenge. Analysis speed and system ruggedness are key requirements for bioanalysis of thousands of samples per day. The tasks involved in LC/MS analysis are readily divided into three areas, sample preparation/liquid handling, LC/MS method building/sample analysis, and data processing. Several automation and multitasking strategies were developed and implemented to minimize plating and liquid handling errors, reduce dead times within the analysis cycle, and allow for comprehensive review of data. Delivering multiple samples to multiple injectors allows the autosampler time to complete its wash cycles and aspirate the next set of samples while the previous set is being analyzed. A dual-column chromatography system provides column cycling and peak stacking and allows rapid throughput using conventional LC equipment. Collecting all data for a compound into a single file greatly reduces the number of data files collected, increases the speed of data collection, allows rugged and complete review of all data, and provides facile data management. The described systems have analyzed over 40 000 samples per month for two years and have the capacity for over 2000 samples per instrument per day.

Entities:  

Mesh:

Year:  2001        PMID: 11321300     DOI: 10.1021/ac0013251

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Application of parallel liquid chromatography/mass spectrometry for high throughput microsomal stability screening of compound libraries.

Authors:  Rongda Xu; Csaba Nemes; Kelly M Jenkins; Robyn A Rourick; Daniel B Kassel; Charles Z C Liu
Journal:  J Am Soc Mass Spectrom       Date:  2002-02       Impact factor: 3.109

2.  Particle discriminator interface for nanoflow ESI-MS.

Authors:  Bradley B Schneider; Vladimir I Baranov; Hassan Javaheri; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2003-11       Impact factor: 3.109

3.  Quantitative-qualitative data acquisition using a benchtop Orbitrap mass spectrometer.

Authors:  Kevin P Bateman; Markus Kellmann; Helmut Muenster; Robert Papp; Lester Taylor
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-06       Impact factor: 3.109

4.  Spirocyclic chromanes exhibit antiplasmodial activities and inhibit all intraerythrocytic life cycle stages.

Authors:  Bracken F Roberts; Iredia D Iyamu; Sukjun Lee; Eunyoung Lee; Lawrence Ayong; Dennis E Kyle; Yu Yuan; Roman Manetsch; Debopam Chakrabarti
Journal:  Int J Parasitol Drugs Drug Resist       Date:  2016-02-12       Impact factor: 4.077

5.  4-Nitro styrylquinoline is an antimalarial inhibiting multiple stages of Plasmodium falciparum asexual life cycle.

Authors:  Bracken F Roberts; Yongsheng Zheng; Jacob Cleaveleand; Sukjun Lee; Eunyoung Lee; Lawrence Ayong; Yu Yuan; Debopam Chakrabarti
Journal:  Int J Parasitol Drugs Drug Resist       Date:  2017-02-21       Impact factor: 4.077

Review 6.  Current status and future directions of high-throughput ADME screening in drug discovery.

Authors:  Wilson Z Shou
Journal:  J Pharm Anal       Date:  2020-05-23