Literature DB >> 11321296

Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay.

S B Cheng1, C D Skinner, J Taylor, S Attiya, W E Lee, G Picelli, D J Harrison.   

Abstract

A six-channel microfluidic immunoassay device with a scanned fluorescence detection system is described. Six independent mixing, reaction, and separation manifolds are integrated within one microfluidic wafer, along with two optical alignment channels. The manifolds are operated simultaneously and data are acquired using a singlepoint fluorescence detector with a galvano-scanner to step between separation channels. A detection limit of 30 pM was obtained for fluorescein with the scanning detector, using a 7.1-Hz sampling rate for each of the reaction manifolds and alignment channels (57-Hz overall sampling rate). Simultaneous direct immunoassays for ovalbumin and for anti-estradiol were performed within the microfluidic device. Mixing, reaction, and separation could be performed within 60 s in all cases and within 30 s under optimized conditions. Simultaneous calibration and analysis could be performed with calibrant in several manifolds and sample in the other manifolds, allowing a complete immunoassay to be run within 30 s. Careful chip conditioning with methanol, water, and 0.1 M NaOH resulted in peak height RSD values of 3-8% (N = 5 or 6), allowing for cross-channel calibration. The limit of detection (LOD) for an anti-estradial assay obtained in any single channel was 4.3 nM. The LOD for the cross-channel calibration was 6.4 nM. Factors influencing chip and detection system design and performance are discussed in detail.

Entities:  

Year:  2001        PMID: 11321296     DOI: 10.1021/ac0007938

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

Review 1.  Integrated microfluidic platform for oral diagnostics.

Authors:  Amy E Herr; Anson V Hatch; William V Giannobile; Daniel J Throckmorton; Huu M Tran; James S Brennan; Anup K Singh
Journal:  Ann N Y Acad Sci       Date:  2007-03       Impact factor: 5.691

2.  Experimental investigation and computational modeling of hydrodynamics in bifurcating microchannels.

Authors:  Vijayakumar Janakiraman; Sudeep Sastry; Jaikrishnan R Kadambi; Harihara Baskaran
Journal:  Biomed Microdevices       Date:  2008-06       Impact factor: 2.838

3.  Elastomeric microchip electrospray emitter for stable cone-jet mode operation in the nanoflow regime.

Authors:  Ryan T Kelly; Keqi Tang; Daniel Irimia; Mehmet Toner; Richard D Smith
Journal:  Anal Chem       Date:  2008-04-18       Impact factor: 6.986

4.  Optimization of a microfluidic electrophoretic immunoassay using a Peltier cooler.

Authors:  Nikita Mukhitov; Lian Yi; Adrian M Schrell; Michael G Roper
Journal:  J Chromatogr A       Date:  2014-09-22       Impact factor: 4.759

Review 5.  Passive micropumping in microfluidics for point-of-care testing.

Authors:  Linfeng Xu; Anyang Wang; Xiangpeng Li; Kwang W Oh
Journal:  Biomicrofluidics       Date:  2020-05-27       Impact factor: 2.800

6.  Parallel separations using capillary electrophoresis on a multilane microchip with multiplexed laser-induced fluorescence detection.

Authors:  Irena Nikcevic; Aigars Piruska; Kenneth R Wehmeyer; Carl J Seliskar; Patrick A Limbach; William R Heineman
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

Review 7.  Multiplexed detection and applications for separations on parallel microchips.

Authors:  John F Dishinger; Robert T Kennedy
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

8.  Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection.

Authors:  Nongnoot Wongkaew; Peng He; Vanessa Kurth; Werasak Surareungchai; Antje J Baeumner
Journal:  Anal Bioanal Chem       Date:  2013-05-17       Impact factor: 4.142

Review 9.  Microfabrication and applications of opto-microfluidic sensors.

Authors:  Daiying Zhang; Liqiu Men; Qiying Chen
Journal:  Sensors (Basel)       Date:  2011-05-18       Impact factor: 3.576

Review 10.  A Review of the Nucleic Acid-Based Lateral Flow Assay for Detection of Breast Cancer from Circulating Biomarkers at a Point-of-Care in Low Income Countries.

Authors:  Busiswa Dyan; Palesa Pamela Seele; Amanda Skepu; Phumlane Selby Mdluli; Salerwe Mosebi; Nicole Remaliah Samantha Sibuyi
Journal:  Diagnostics (Basel)       Date:  2022-08-15
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.