Literature DB >> 11320471

Tensile bond strength of resin-modified glass-ionomer cement to microabraded and silica-coated or tin-plated high noble ceramic alloy.

J M Swartz1, R D Davis, J D Overton.   

Abstract

PURPOSE: The purpose of this study was to evaluate the influence of alloy surface microabrasion, silica coating, or microabrasion plus tin plating on the tensile bond strengths between a resin-modified glass-ionomer luting cement and a high-noble alloy. Bond strength between the microabraded alloy specimens and conventional glass-ionomer cement or resin cement were included for comparison.
MATERIALS AND METHODS: One hundred twenty uniform size, disk-shaped specimens were cast in a noble metal alloy and divided into 6 groups (n = 10 pairs/group). The metal surfaces of the specimens in each group were treated and cemented as follows. Group 1: No surface treatment (as cast, control), cemented with a resin-modified glass-ionomer cement. Group 2: Microabrasion with 50-microm aluminum oxide particles, resin-modified glass-ionomer cement. Group 3: A laboratory microabrasion and silica coating system, resin-modified glass-ionomer cement. Group 4: Microabrasion and tin-plating, resin-modified glass-ionomer cement. Group 5: Microabrasion only, conventional glass-ionomer cement. Group 6: Microabrasion and tin-plating, conventional resin cement. The uniaxial tensile bond strength for each specimen pair was determined using an Instron Universal Testing Machine (Instron Corp, Canton, MA). Results were analyzed using a one-way analysis of variance (alpha = 0.05) and a Tukey post-hoc analysis.
RESULTS: Mean bond strength: Group 1: 3.6 (+/- 1.5) MPa. Group 2: 4.2 (+/-0.5) MPa. Group 3: 6.7 (+/- 0.9) MPa. Group 4: 10.6 (+/- 1.8) MPa. Group 5: 1.1 (+/- 0.4) MPa. Group 6: 14.6 (+/- 2.3) MPa. Group 6 was significantly stronger than Group 4. The bond strength of specimens cemented with the resin-modified glass-ionomer cement using microabrasion and tin-plating (Group 4) was significantly stronger than all other groups except the resin cement with microabrasion and tin-plating (Group 6).
CONCLUSION: Microabraded and tin-plated alloy specimens luted with the resin-modified glass-ionomer cement resulted in the greatest mean tensile strengths for the resin-modified glass-ionomer cement groups. This strength was 73% of the mean tensile strength of microabraded specimens luted with resin cement.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11320471     DOI: 10.1111/j.1532-849x.2000.00195.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

1.  Effect of Sulfur-Containing Primers for Noble Metals on the Bond Strength of Self-Cured Acrylic Resin.

Authors:  Keiichi Yoshida
Journal:  Dent J (Basel)       Date:  2017-06-20

2.  Influence of Non-Thermal Atmospheric Pressure Plasma Treatment on Retentive Strength between Zirconia Crown and Titanium Implant Abutment.

Authors:  Dae-Sung Kim; Jong-Ju Ahn; Gyoo-Cheon Kim; Chang-Mo Jeong; Jung-Bo Huh; So-Hyoun Lee
Journal:  Materials (Basel)       Date:  2021-05-01       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.