Literature DB >> 11318573

Quantification of Cryptosporidium parvum oocysts in mouse fecal specimens using immunomagnetic particles and two-color flow cytometry.

D M Moss1, M J Arrowood.   

Abstract

Although single-color flow cytometry has been shown to be more sensitive than fluorescence microscopy for the quantification of Cryptosporidium parvum oocysts, this method has not been optimized. Monoclonal antibody OW50, specific to the cell wall of oocysts, was conjugated to superparamagnetic particles, to fluorescein isothiocyanate, and to r-phycoerythrin. The oocysts were then double stained with the fluorochrome-labeled OW50 and were placed in tubes with known numbers of highly fluorescent polystyrene beads, allowing quantification of the oocysts without dependence on acquired sample volume by flow cytometry. Data from 2-color flow cytometry using logical gating of the oocysts and beads showed a linear relationship between dilutions of a purified oocyst suspension and the mean numbers of oocysts detected (r2 = 1.00). An average of 15 purified oocysts/ml were counted in a dilution with a theoretical concentration of 12 oocysts/ml. Known numbers of purified oocysts were seeded into normal mouse fecal specimens, captured by OW50-labeled immunomagnetic particles, eluted with 5% potassium dichromate at low pH, and double stained with fluorochrome-labeled OW50. By flow cytometry, the mean recovery was 43.1% (+/-8.3%), and as few as 133 oocysts were detected. The captured and eluted oocysts were infective in neonatal BALB/c mice. This 2-color flow cytometry method, used in conjunction with the capture and elution of oocysts by and from immunomagnetic particles, provides a powerful tool for not only the quantification and purification of C. parvum oocysts from different sources but also for the characterization of oocysts in vitro and in vivo.

Entities:  

Mesh:

Year:  2001        PMID: 11318573     DOI: 10.1645/0022-3395(2001)087[0406:QOCPOI]2.0.CO;2

Source DB:  PubMed          Journal:  J Parasitol        ISSN: 0022-3395            Impact factor:   1.276


  4 in total

1.  Detection of Cyclospora cayetanensis oocysts in human fecal specimens by flow cytometry.

Authors:  Brent R Dixon; Jeff M Bussey; Lorna J Parrington; Monique Parenteau
Journal:  J Clin Microbiol       Date:  2005-05       Impact factor: 5.948

2.  Purification of Enterocytozoon bieneusi spores from stool specimens by gradient and cell sorting techniques.

Authors:  Zuzana Kucerova; Hercules Moura; Gordon J Leitch; Rama Sriram; Caryn Bern; Vivian Kawai; Daniel Vargas; Robert H Gilman; Eduardo Ticona; Aldo Vivar; Govinda S Visvesvara
Journal:  J Clin Microbiol       Date:  2004-07       Impact factor: 5.948

3.  A historical review of the techniques of recovery of parasites for their detection in human stools.

Authors:  Felipe Augusto Soares; Aline do Nascimento Benitez; Bianca Martins Dos Santos; Saulo Hudson Nery Loiola; Stefany Laryssa Rosa; Walter Bertequini Nagata; Sandra Valéria Inácio; Celso Tetsuo Nagase Suzuki; Katia Denise Saraiva Bresciani; Alexandre Xavier Falcão; Jancarlo Ferreira Gomes
Journal:  Rev Soc Bras Med Trop       Date:  2020-06-01       Impact factor: 1.581

4.  Detection of Schistosoma mansoni eggs in feces through their interaction with paramagnetic beads in a magnetic field.

Authors:  Candida Fagundes Teixeira; Erli Neuhauss; Renata Ben; Juliano Romanzini; Carlos Graeff-Teixeira
Journal:  PLoS Negl Trop Dis       Date:  2007-11-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.