Literature DB >> 11317394

Influence of different dentinal substrates on the tensile bond strength of three adhesive systems.

A Muench1, E M da Silva, R Y Ballester.   

Abstract

PURPOSE: To evaluate the influence of the method and duration of storage for different types of teeth prior to their use in dentin bonding tests with three adhesive systems.
MATERIALS AND METHODS: Recently extracted sound human molars, bovine incisors, and human caries-free molars obtained from exhumed bones 5 years postmortem were used. The latter group of teeth was kept dry for 6 months, and then rehydrated in distilled water over a period of 30 days. The adhesive systems used were Prime&Bond 2.1. Single Bond, and Etch&Prime 3.0. Human teeth were embedded longitudinally in PVC cylinders; bovine incisors were embedded leaving the buccal surface exposed. Flat dentin surfaces were cut with a diamond disk and ground with up to 600-grit SiC paper. Adhesives were applied following manufacturers' instructions. A silicone mold with a cone-shaped perforation (4.5 mm high and 2 mm diameter at the smallest) was fixed on the dentin surface and filled with TPH composite resin. The specimens were stored in distilled water for two weeks before testing.
RESULTS: ANOVA did not detect statistical differences either in the main factors (substrate and adhesive system) or in their interaction (p > 0.05). Tensile bond strength averages ranged from 11.6 to 14.2 MPa. The dentinal substrates showed similar performances, regardless of the adhesives tested.
CONCLUSION: The differences among the three dentin substrates do not appear to be critical for the tensile bond strength test for the three adhesive systems. The adhesive systems presented similar bond strengths.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11317394

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  3 in total

1.  Orthodontic shear bond strength and ultimate load tests of CAD/CAM produced artificial teeth.

Authors:  Christoph J Roser; Thomas Rückschloß; Andreas Zenthöfer; Peter Rammelsberg; Christopher J Lux; Stefan Rues
Journal:  Clin Oral Investig       Date:  2022-08-18       Impact factor: 3.606

Review 2.  Validity of bond strength tests: A critical review: Part I.

Authors:  Kantheti Sirisha; Tankonda Rambabu; Yalavarthi Ravi Shankar; Pabbati Ravikumar
Journal:  J Conserv Dent       Date:  2014-07

3.  Nanoleakage phenomenon on deproteinized human dentin.

Authors:  Patrícia de Britto Pereira Garcia Duarte; Eduardo Moreira da Silva
Journal:  J Appl Oral Sci       Date:  2007-08       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.