Literature DB >> 11310761

Laser in situ keratomileusis for the correction of hyperopia from +0.50 to +11.50 diopters with the Keracor 117C laser.

K F Tabbara1, H F El-Sheikh, S M Islam.   

Abstract

PURPOSE: To evaluate excimer laser in situ keratomileusis (LASIK) for the correction of hyperopia.
METHODS: We reviewed retrospectively the medical records of 46 patients treated with LASIK for hyperopia. All patients had a complete ophthalmologic evaluation. The corneal bed was ablated using the Bausch & Lomb Chiron Keracor 117C excimer laser to create a paracentral annular ablation under a nasally hinged 160-microm corneal flap with the Chiron Automatic Corneal Shaper microkeratome. Follow-up was a minimum of 6 months.
RESULTS: Eighty eyes of 46 patients (23 males and 23 females) were included. Age ranged from 18 to 65 years (mean, 42 yr). The range of preoperative spherical equivalent refraction was +0.50 to +11.50 D (mean, +3.40 D). Mean postoperative spherical equivalent refraction at 6 months was +0.26 D. Six months after surgery, 35 eyes (44%) achieved uncorrected visual acuity of 20/20 or better and 78 eyes (97.5%) achieved 20/40 or better. Forty-six eyes (58%) had a postoperative spherical equivalent refraction within +/-0.50 D of attempted correction, and 67 eyes (84%) were within +/-1.00 D of attempted correction. When using the Bausch & Lomb Chiron Keracor 117C excimer laser to correct hyperopia, eyes with a spherical equivalent refraction less +2.00 D should be overcorrected by 25%, +2.00 to +4.00 D by 30%, and over +4.00 by 40%. The positive cylinder should be overcorrected by 10%.
CONCLUSIONS: LASIK was safe and effective in the treatment of hyperopia from +0.50 to +11.50 D. Regression following LASIK for hyperopia remains a problem. A special nomogram was required to achieve results comparable with those for myopia.

Entities:  

Mesh:

Year:  2001        PMID: 11310761     DOI: 10.3928/1081-597X-20010301-05

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

1.  Conductive keratoplasty for the correction of hyperopia.

Authors:  P A Asbell; R K Maloney; J Davidorf; P Hersh; M McDonald; E Manche
Journal:  Trans Am Ophthalmol Soc       Date:  2001

2.  Conductive keratoplasty: a radiofrequency-based technique for the correction of hyperopia.

Authors:  Marguerite B McDonald
Journal:  Trans Am Ophthalmol Soc       Date:  2005

3.  Predictability and stability of refraction with increasing optical zone diameter in hyperopic LASIK.

Authors:  Mostafa A El-Helw; Ahmed M Emarah
Journal:  Clin Ophthalmol       Date:  2010-05-14

Review 4.  Errors in Treatment of Lower-order Aberrations and Induction of Higher-order Aberrations in Laser Refractive Surgery.

Authors:  Brad E Kligman; Brandon J Baartman; William J Dupps
Journal:  Int Ophthalmol Clin       Date:  2016

5.  [Laser in situ keratomileusis for correction of hyperopia and hyperopic astigmatism using a scanning spot excimer laser. Results of a prospective clinical study after 1 year].

Authors:  T Kohnen; A Mirshahi; M Cichocki; J Bühren; G W K Steinkamp
Journal:  Ophthalmologe       Date:  2003-12       Impact factor: 1.059

6.  The effect of preoperative keratometry on visual outcomes after moderate myopic LASIK.

Authors:  Steven M Christiansen; Marcus C Neuffer; Shameema Sikder; Rodmehr T Semnani; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2012-03-21

7.  Effect of Flat Cornea on Visual Outcome after LASIK.

Authors:  Engy Mohamed Mostafa
Journal:  J Ophthalmol       Date:  2015-11-29       Impact factor: 1.909

8.  LASIK and PRK in hyperopic astigmatic eyes: is early retreatment advisable?

Authors:  Andreas Frings; Gisbert Richard; Johannes Steinberg; Vasyl Druchkiv; Stephan Johannes Linke; Toam Katz
Journal:  Clin Ophthalmol       Date:  2016-03-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.