Literature DB >> 11309792

Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study.

K Yamamoto1, I C Clarke, T Masaoka, H Oonishi, P A Williams, V D Good, A Imakiire.   

Abstract

Ultrahigh molecular weight polyethylene (PE) cups with 0, 2.5, 50, 100, and 150 Mrad radiation treatments were run in a hip simulator for comparison of the microwear phenomena on the cup surfaces with the corresponding debris morphology. In general, the size and frequency of the PE surface fibrils and the size of the retrieved PE debris decreased with increasing radiation dose. The fibril size and shape on the cup surfaces were well correlated with the radiation dose. The fibrillar shape and size were found to be proportional to the square root of the radiation dose. However, the trend for size and shape factors of the wear debris related to the radiation dose was weak at best. Thus, the morphology of the PE fibrils on the cup surfaces was more sensitive to variations in the radiation dose than the actual wear debris. The wear response appeared to be a three-step process, which was dependent on the formation of surface nodules or ripples, the teasing out of surface fibrils, and the toughness of the PE matrix in releasing a wear fibril to form a debris particle. The tougher PE became with increasing radiation dose, the harder it was for the PE fibrils to break out into wear particles.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11309792     DOI: 10.1002/1097-4636(200107)56:1<65::aid-jbm1069>3.0.co;2-z

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

1.  Wear mode and wear mechanism of retrieved acetabular cups.

Authors:  Kengo Yamamoto; Atsuhiro Imakiire; Toshinori Masaoka; Takaaki Shishido; Tatsuro Mizoue; Ian C Clarke; Hiromu Shoji; Keiichi Kawanabe; Jiro Tamura
Journal:  Int Orthop       Date:  2003-06-21       Impact factor: 3.075

2.  Characteristics of highly cross-linked polyethylene wear debris in vivo.

Authors:  Ryan M Baxter; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

3.  Do tissues from THA revision of highly crosslinked UHMWPE liners contain wear debris and associated inflammation?

Authors:  Ryan M Baxter; Theresa A Freeman; Steven M Kurtz; Marla J Steinbeck
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.