Literature DB >> 11309172

Umbilical vein blood flow in fetuses with normal and lean umbilical cord.

E Di Naro1, F Ghezzi, L Raio, M Franchi, V D'Addario, G Lanzillotti, H Schneider.   

Abstract

OBJECTIVE: To evaluate whether umbilical vascular coiling is correlated with the umbilical vein blood flow profile and to investigate if this is different between fetuses with a lean and those with a normal umbilical cord.
METHODS: Consecutive women with a singleton gestation who delivered at term and who underwent an ultrasound examination within 24 h from delivery were studied. Umbilical cord and vessel areas were calculated. Umbilical vein blood flow parameters were obtained by digital color Doppler velocity profile integration. After delivery, the umbilical coiling index was calculated.
RESULTS: One hundred and sixteen women were studied. Twelve (10.3%) had a lean umbilical cord (area < 10th centile). A significant correlation was found between the umbilical coiling index and the umbilical vein blood flow (r = 0.67, P < 0.001). A significant difference between fetuses with and without a lean cord was found in terms of: umbilical coiling index (0.18 +/- 0.08 vs. 0.29 +/- 0.09, P < 0.005), cord area (87.6 +/- 5.1 mm2 vs. 200.6 +/- 34.6 mm2, P < 0.001), Wharton's jelly amount (25.7 +/- 10.3 mm2 vs. 122.1 +/- 33.4 mm2, P < 0.001), umbilical vein blood flow (93.7 +/- 17.8 ml/kg per min vs. 126.0 +/- 23.4 ml/kg per min, P < 0.001), and umbilical vein blood flow mean velocity (6.6 +/- 2.7 cm/s vs. 9.0 +/- 3.6 cm/s, P < 0.05). The proportion of fetuses with an umbilical vein blood flow < 80 ml/kg per min was higher when the cord was lean than when it was normal (25% vs. 1.9%, P < 0.01).
CONCLUSIONS: Lean umbilical cords differ from normal cords not only from a structural point of view but also in the umbilical vein blood flow characteristics. This could explain the increased incidence of intrapartum complications and fetal growth restriction among fetuses with a lean and/or hypocoiled cord.

Entities:  

Mesh:

Year:  2001        PMID: 11309172     DOI: 10.1046/j.1469-0705.2001.00309.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

Review 1.  Gestation-Specific Changes in the Anatomy and Physiology of Healthy Pregnant Women: An Extended Repository of Model Parameters for Physiologically Based Pharmacokinetic Modeling in Pregnancy.

Authors:  André Dallmann; Ibrahim Ince; Michaela Meyer; Stefan Willmann; Thomas Eissing; Georg Hempel
Journal:  Clin Pharmacokinet       Date:  2017-11       Impact factor: 6.447

2.  Is there any relation between umbilical artery and vein diameter and estimated fetal weight in healthy pregnant women?

Authors:  Aydın Köşüş; Nermin Köşüş; Nilgün Ö Turhan
Journal:  J Med Ultrason (2001)       Date:  2012-05-09       Impact factor: 1.314

3.  Reliability and characteristics of ultrasound measurement of fetal umbilical venous blood flow volume according to the site of measurement.

Authors:  Seiji Kanazawa; Jin Muromoto; Katsusuke Ozawa; Masashi Mikami; Kohei Ogawa; Seiji Wada; Haruhiko Sago
Journal:  J Med Ultrason (2001)       Date:  2020-01-07       Impact factor: 1.314

Review 4.  The development, structure and blood flow within the umbilical cord with particular reference to the venous system.

Authors:  Jacqueline Spurway; Patricia Logan; Sokcheon Pak
Journal:  Australas J Ultrasound Med       Date:  2015-12-31
  4 in total