Literature DB >> 11306530

Index matching to improve optical coherence tomography imaging through blood.

M Brezinski1, K Saunders, C Jesser, X Li, J Fujimoto.   

Abstract

BACKGROUND: Most myocardial infarctions are caused by the rupture of small rather than large plaques in the arteries of the heart that are beyond the detection limit of current technologies. METHODS AND
RESULTS: Recently, optical coherence tomography (OCT) has demonstrated considerable potential as a method for high-resolution assessment of vulnerable plaque. However, intravascular OCT imaging is complicated by the need to remove blood from the imaging field because blood results in substantial signal attenuation. This work examines index matching as a method for increasing penetration. Index matching is based on the hypothesis that the predominant source of scattering in blood is the difference in refractive index between the cytoplasm of erythrocytes and serum. By increasing the refractive index of serum to a value near that of the cytoplasm, or index matching, scattering can be substantially reduced. The concept was tested with a system that pumped blood in vitro through transparent tubing. The test compounds, dextran and intravenous contrast agent, both led to significant improvements in penetration (69+/-12% and 45+/-4%). No significant effect was seen with the saline control. For dextran, the effect could not be attributed to reductions of red cell number or volume because changes in these parameters were not different from the control. In the case of intravenous contrast, a small but significant relative reduction in red cell volume was seen.
CONCLUSIONS: This study demonstrates the feasibility of index matching for improving OCT imaging through blood. Future studies are required to identify compounds for effective index matching in vivo.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11306530     DOI: 10.1161/01.cir.103.15.1999

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  25 in total

1.  Guidance of aortic ablation using optical coherence tomography.

Authors:  Nirlep A Patel; Xingde Li; Debra L Stamper; James G Fujimoto; Mark E Brezinski
Journal:  Int J Cardiovasc Imaging       Date:  2003-04       Impact factor: 2.357

2.  Dual-element needle transducer for intravascular ultrasound imaging.

Authors:  Sangpil Yoon; Min Gon Kim; Jay A Williams; Changhan Yoon; Bong Jin Kang; Nestor Cabrera-Munoz; K Kirk Shung; Hyung Ham Kim
Journal:  J Med Imaging (Bellingham)       Date:  2015-04-13

Review 3.  Optical coherence tomography for imaging the vulnerable plaque.

Authors:  Guillermo J Tearney; Ik-Kyung Jang; Brett E Bouma
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

4.  Velocity variation assessment of red blood cell aggregation with spectral domain Doppler optical coherence tomography.

Authors:  Xiangqun Xu; Lingfeng Yu; Zhongping Chen
Journal:  Ann Biomed Eng       Date:  2010-05-15       Impact factor: 3.934

5.  Feasibility of Doppler variance imaging for red blood cell aggregation characterization.

Authors:  Xiangqun Xu; Yeh-Chan Ahn; Zhongping Chen
Journal:  J Biomed Opt       Date:  2009 Nov-Dec       Impact factor: 3.170

6.  Virtual histology of the human heart using optical coherence tomography.

Authors:  Christina M Ambrosi; Nader Moazami; Andrew M Rollins; Igor R Efimov
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

7.  Use of an oxygen-carrying blood substitute to improve intravascular optical coherence tomography imaging.

Authors:  Khiet C Hoang; Ahmad Edris; Jianping Su; David S Mukai; Sari Mahon; Artiom D Petrov; Morton Kern; Chowdhury Ashan; Zhongping Chen; Bruce J Tromberg; Jagat Narula; Matthew Brenner
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

8.  Optimal flushing agents for integrated optical and acoustic imaging systems.

Authors:  Jiawen Li; Hataka Minami; Earl Steward; Teng Ma; Dilbahar Mohar; Claire Robertson; Kirk Shung; Qifa Zhou; Pranav Patel; Zhongping Chen
Journal:  J Biomed Opt       Date:  2015-05       Impact factor: 3.170

9.  Frequency-domain optical coherence tomography assessment of human carotid atherosclerosis using saline flush for blood clearance without balloon occlusion.

Authors:  C A Given; G F Attizzani; M R Jones; C N Ramsey; W H Brooks; M A Costa; H G Bezerra
Journal:  AJNR Am J Neuroradiol       Date:  2013-02-07       Impact factor: 3.825

10.  Characterization of atherosclerotic plaques by laser speckle imaging.

Authors:  Seemantini K Nadkarni; Brett E Bouma; Tina Helg; Raymond Chan; Elkan Halpern; Alexandra Chau; Milan Singh Minsky; Jason T Motz; Stuart L Houser; Guillermo J Tearney
Journal:  Circulation       Date:  2005-08-01       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.