Estimation of spleen volume using MR imaging and a random marking technique.

M Mazonakis1, J Damilakis, T Maris, P Prassopoulos, N Gourtsoyiannis.   

Abstract

The aim of this study was to apply a random marking volumetric technique in MR images for estimation of spleen volume. The MR imaging was performed in phantoms and 16 patients with indications unrelated to splenic disease. Images were transferred to a workstation to perform volumetric measurements using the random marking technique and the conventional technique of manual planimetry. Two observers independently measured splenic volume in order to evaluate reproducibility of both volumetric techniques. Phantom experiments revealed that the accuracy of the random marking technique and manual planimetry was approximately the same. In vivo splenic volume measurements derived from both volumetric techniques were highly correlated (r = 0.99, p < 0.0001). For both observers intraobserver variation was found to be lower with the random marking technique than with manual planimetry. Interobserver coefficient of variation using the manual planimetry was 4.6% and was reduced to 2.9% by adopting the random marking technique. The random marking technique was almost two times faster than the manual planimetry. The combination of the random marking technique with MR imaging might provide accurate, reproducible, quick splenic volume estimations.

Entities:  

Mesh:

Year:  2000        PMID: 11305567     DOI: 10.1007/s003300000551

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  11 in total

1.  Stereological estimation of total intracranial volume on CT images.

Authors:  Michael Mazonakis; Spyros Karampekios; John Damilakis; Argyro Voloudaki; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2004-02-06       Impact factor: 5.315

2.  Spleen volume on CT and the effect of abdominal trauma.

Authors:  Cinthia Cruz-Romero; Sheela Agarwal; Hani H Abujudeh; James Thrall; Peter F Hahn
Journal:  Emerg Radiol       Date:  2016-05-11

3.  A double-blind, placebo-controlled trial of ruxolitinib for myelofibrosis.

Authors:  Srdan Verstovsek; Ruben A Mesa; Jason Gotlib; Richard S Levy; Vikas Gupta; John F DiPersio; John V Catalano; Michael Deininger; Carole Miller; Richard T Silver; Moshe Talpaz; Elliott F Winton; Jimmie H Harvey; Murat O Arcasoy; Elizabeth Hexner; Roger M Lyons; Ronald Paquette; Azra Raza; Kris Vaddi; Susan Erickson-Viitanen; Iphigenia L Koumenis; William Sun; Victor Sandor; Hagop M Kantarjian
Journal:  N Engl J Med       Date:  2012-03-01       Impact factor: 91.245

4.  Determination of splenomegaly by coronal oblique length on CT.

Authors:  Serra Ozbal Gunes; Yeliz Akturk
Journal:  Jpn J Radiol       Date:  2017-11-16       Impact factor: 2.374

5.  Robust Multicontrast MRI Spleen Segmentation for Splenomegaly Using Multi-Atlas Segmentation.

Authors:  Yuankai Huo; Jiaqi Liu; Zhoubing Xu; Robert L Harrigan; Albert Assad; Richard G Abramson; Bennett A Landman
Journal:  IEEE Trans Biomed Eng       Date:  2018-02       Impact factor: 4.538

6.  Efficient stereological approaches for the volumetry of a normal or enlarged spleen from MDCT images.

Authors:  Michalis Mazonakis; John Stratakis; John Damilakis
Journal:  Eur Radiol       Date:  2015-01-13       Impact factor: 5.315

7.  Comparison Between Liver Stiffness Measurement by Fibroscan and Splenic Volume Index as NonInvasive Tools for the Early Detection of Oxaliplatin-induced Hepatotoxicity.

Authors:  Youssef Bouferraa; Yolla Haibe; Elio Jabra; Maya Charafeddine; Malek Kreidieh; Randa Raad; Sally Temraz; Deborah Mukherji; Firas Ershaid; Nadim Muallem; Walid Faraj; Mohamad Khalife; Rania A Eid; Ali Shamseddine
Journal:  J Clin Exp Hepatol       Date:  2021-06-15

8.  Retrospective measurement of different size parameters of non-radiated rectal cancer on MR images and pathology slides and their comparison.

Authors:  Michael Torkzad; Johan Lindholm; Anna Martling; Lennart Blomqvist
Journal:  Eur Radiol       Date:  2003-05-10       Impact factor: 5.315

9.  Standard Splenic Volume Estimation in North Indian Adult Population: Using 3D Reconstruction of Abdominal CT Scan Images.

Authors:  Adil Asghar; Dushyant Agrawal; S M Yunus; P K Sharma; S H H Zaidi; Aruna Sinha
Journal:  Anat Res Int       Date:  2011-03-08

10.  Effect of Breath Holding on Spleen Volume Measured by Magnetic Resonance Imaging.

Authors:  Yusuke Inoue; Ai Nakajima; Shinya Mizukami; Hirofumi Hata
Journal:  PLoS One       Date:  2013-06-26       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.