Literature DB >> 11305534

Cardiac contusion in blunt chest trauma: a combined study of transesophageal echocardiography and cardiac troponin I determination.

F Mori1, A Zuppiroli, A Ognibene, S Favilli, G Galeota, A Peris, G De Saint Pierre, A Dolara.   

Abstract

BACKGROUND: The role of cardiac troponin I (cTnI) is well established in acute myocardial ischemia. However, its role in myocardial contusion remains to be clarified. Since transesophageal echocardiography (TEE) appears, at present, to be the best method for the diagnosis of myocardial contusion, the aim of this study was to measure the concentration of cTnI in patients with blunt chest trauma studied using TEE.
METHODS: Thirty-two patients (27 males, 5 females, mean age 44+/-20 years), admitted to the Trauma Center of our Institution with clinical and/or radiological signs of acute blunt chest trauma, underwent biplane TEE within 24 hours of injury; serial blood samples were taken to measure cTnI levels (normal values < 0.4 ng/ml), using fluorimetric enzyme immunoassay.
RESULTS: Abnormal levels of cTnI were found in 17 patients (53%): 7 patients had levels of cTnI between 0.4 and 1 ng/ml, whereas 10 patients had levels > 1 ng/ml. Segmental wall motion abnormalities consistent with myocardial contusion could be identified by echocardiography in 6/10 patients with cTnI levels > 1 ng/ml (60%) but in no patients with normal cTnI levels or with titers between 0.4 and 1 ng/ml; mean cTnI levels showed a significant difference between the two groups of patients with and without echocardiographic signs of myocardial contusion (2.6+/-1.6 vs 0.6+/-1.4 ng/ml, p < 0.001).
CONCLUSIONS: Abnormal titers of cTnI suggesting myocardial contusion may be found in more than half of patients with blunt chest trauma; however, myocardial injury can be detected by TEE only for cTnI levels > 1 ng/ml; cTnI concentrations ranging between 0.4 and 1 ng/ml might be indicative of myocardial microlesions, not detectable by echocardiography, even if TEE is used; cTnI assay could therefore be suggested as a screening test before performing TEE after blunt chest trauma.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11305534

Source DB:  PubMed          Journal:  Ital Heart J        ISSN: 1129-471X


  9 in total

1.  Cardio-embolic stroke following remote blunt chest trauma.

Authors:  Sonali Arora; Auras R Atreya; Srikanth C Penumetsa; William L Hiser
Journal:  J Cardiovasc Dis Res       Date:  2013-03-06

Review 2.  Myocardial contusion injury: redefining the diagnostic algorithm.

Authors:  M K Bansal; S Maraj; D Chewaproug; A Amanullah
Journal:  Emerg Med J       Date:  2005-07       Impact factor: 2.740

Review 3.  Troponin I in the intensive care unit setting: from the heart to the heart.

Authors:  Chiara Lazzeri; Manuela Bonizzoli; Giovanni Cianchi; Gian Franco Gensini; Adriano Peris
Journal:  Intern Emerg Med       Date:  2008-03-07       Impact factor: 3.397

4.  Myocardial infarction after blunt chest trauma: usefulness of cardiac ECG-gated CT and MRI for positive and aetiologic diagnosis.

Authors:  Gregory Malbranque; Jean Michel Serfaty; Dominique Himbert; Philippe Gabriel Steg; Jean Pierre Laissy
Journal:  Emerg Radiol       Date:  2011-01-14

5.  [Myocardial infarction as cause of an accident. The role of multislice CT in polytrauma management, differential diagnosis and insurance aspects].

Authors:  C Kleber; B Oswald; H J Bail; N P Haas; F Kandziora
Journal:  Unfallchirurg       Date:  2008-12       Impact factor: 1.000

6.  Ventricular septal defect following blunt chest trauma.

Authors:  Lisa Ryan; David L Skinner; Reitze N Rodseth
Journal:  J Emerg Trauma Shock       Date:  2012-04

Review 7.  Diagnosing Myocardial Contusion after Blunt Chest Trauma.

Authors:  Zahra Alborzi; Vahid Zangouri; Shahram Paydar; Zahra Ghahramani; Masih Shafa; Bizhan Ziaeian; Mohammad Reza Radpey; Armin Amirian; Shahin Khodaei
Journal:  J Tehran Heart Cent       Date:  2016-04-13

8.  Diagnostic approach for myocardial contusion: a retrospective evaluation of patient data and review of the literature.

Authors:  Esther M M Van Lieshout; Michael H J Verhofstad; Dirk Jan T Van Silfhout; Eric A Dubois
Journal:  Eur J Trauma Emerg Surg       Date:  2020-01-25       Impact factor: 3.693

9.  Blunt Cardiac Injury in Patients With Sternal Fractures.

Authors:  Alexander A Fokin; Joanna Wycech Knight; Kai Yoshinaga; Ayesha T Abid; Robert Grady; Amaris L Alayon; Ivan Puente
Journal:  Cureus       Date:  2022-03-04
  9 in total