Literature DB >> 11300587

Real-time spatial compound imaging: application to breast, vascular, and musculoskeletal ultrasound.

R R Entrekin1, B A Porter, H H Sillesen, A D Wong, P L Cooperberg, C H Fix.   

Abstract

Real-time spatial compound imaging (SonoCT) is an ultrasound technique that uses electronic beam steering of a transducer array to rapidly acquire several (three to nine) overlapping scans of an object from different view angles. These single-angle scans are averaged to form a multiangle compound image that is updated in real time with each subsequent scan. Compound imaging shows improved image quality compared with conventional ultrasound, primarily because of reduction of speckle, clutter, and other acoustic artifacts. Early clinical experience suggests that real-time spatial compound imaging can provide improved contrast resolution and tissue differentiation that is beneficial for imaging the breast, peripheral blood vessels, and musculoskeletal injuries. Future development of real-time spatial compound imaging will help address the bulk of general imaging applications by extending this technology to curved array transducers, tissue harmonics, panoramic imaging, and three-dimensional sonography.

Entities:  

Mesh:

Year:  2001        PMID: 11300587     DOI: 10.1016/s0887-2171(01)90018-6

Source DB:  PubMed          Journal:  Semin Ultrasound CT MR        ISSN: 0887-2171            Impact factor:   1.875


  29 in total

1.  Ultrasound image matching using genetic algorithms.

Authors:  T S Douglas; S E Solomonidis; W A Sandham; W D Spence
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  [Transrectal ultrasound of the prostate. Current status and prospects].

Authors:  M Zacharias; K V Jenderka; H Heynemann; P Fornara
Journal:  Urologe A       Date:  2002-11       Impact factor: 0.639

3.  High-resolution real-time compound ultrasound imaging of transient protein-losing gastropathy of childhood.

Authors:  Maria-Helena Smet; Elvier Mussen; Nadine Ectors; Luc Breysem
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

4.  Estimation of displacement vectors and strain tensors in elastography using angular insonifications.

Authors:  U Techavipoo; Q Chen; T Varghese; J A Zagzebski
Journal:  IEEE Trans Med Imaging       Date:  2004-12       Impact factor: 10.048

5.  Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding.

Authors:  Udomchai Techavipoo; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

6.  Spatial angular compounding for elastography without the incompressibility assumption.

Authors:  Min Rao; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2005-10       Impact factor: 1.578

7.  Spatial-angular compounding for elastography using beam steering on linear array transducers.

Authors:  Min Rao; Quan Chen; Hairong Shi; Tomy Varghese
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

Review 8.  [New techniques in uro-sonography].

Authors:  H Heynemann; K-V Jenderka; M Zacharias; P Fornara
Journal:  Urologe A       Date:  2004-11       Impact factor: 0.639

9.  A motion compounding technique for speckle reduction in ultrasound images.

Authors:  Cheng-Hsien Lin; Yung-Nien Sun; Chii-Jeng Lin
Journal:  J Digit Imaging       Date:  2009-01-07       Impact factor: 4.056

10.  Medical ultrasound systems.

Authors:  Jeff Powers; Frederick Kremkau
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.